메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Park, Hyun Sik (Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine) Lee, Hong Jin (Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine) An, Hyun Ho (Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine) Moon, Byung Seok (Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine) Lee, Byung Chul (Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine) Kim, Sang Eun (Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine)
저널정보
대한방사성의약품학회 대한방사성의약품학회지 대한방사성의약품학회지 제2권 제2호
발행연도
2016.1
수록면
123 - 131 (9page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Increasing clinical demand for carbon-11 labeled radiopharmaceuticals has triggered technological advances in fields of radiochemistry and automated modules. Even though carbon-11 has a short half-life ($t_{1/2}=20.4min$), the consecutive second production of carbon-11 labeled radiopharmaceutical in one $^{11}C$-synthetic module should be delayed at least over 4 h to avoid the high radiation exposure. We herein aimed to produce two different carbon-11 labeled radiopharmaceuticals ([$^{11}C$]PIB and [$^{11}C$]methionine) by sharing of [$^{11}C$]methylation source in one $^{11}C$-synthetic module. The synthesis of $^{11}C$-labeling reagents ($[^{11}C]CH_3I$ or $[^{11}C]CH_3OTf$) is fully automated using the commercial TRACERlab $FX_{C-pro}$ module and is readily adaptable to $^{11}C$-labeling reactor for [$^{11}C$]PIB as well as another $^{11}C$-labeling apparatus for [$^{11}C$]methionine via the three-way valve. After completing the [$^{11}C$]PIB production, the re-synthesized $[^{11}C]CH_3I$ was passed through the three-way valve connected the polyetheretherketone (PEEK) line and loaded into the C18 Sep-Pak cartridge including the methionine precursor. The labeled product [^${11}C$]methionine was purified by a simple cartridge separation and reformulated into saline. The radiochemical yield of [$^{11}C$]PIB and [$^{11}C$]methionine were $5.3{\pm}0.6%$ and $18.7{\pm}0.8%$ (n.d.c.), respectively, with over 97% of radiochemical purity. The specific activity of [$^{11}C$]PIB was over $110GBq/{\mu}mol$. Total production time of two radiopharmaceuticals needs about 2 h from $1^{st}$ beam irradiation including quality control tests. Final [$^{11}C$]PIB and [$^{11}C$]methionine were satisfied all quality control test standards.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0