Kim Jisoo (Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.) Naohisa Kamiyama (Ultrasound General Imaging, GE HealthCare Japan, Tokyo, Japan) Shunichiro Tanigawa (Ultrasound General Imaging, GE HealthCare Japan, Tokyo, Japan) Yoon Haesung (Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.) Lim Hyun Ji (Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.) Lee Mi-Jung (Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.)
저널정보
대한초음파의학회 ULTRASONOGRAPHY ULTRASONOGRAPHY Vol.43 No.5
발행연도
2024.9
수록면
354 - 363 (10page)
DOI
10.14366/usg.24054

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Purpose: This study assessed the benefits of quality threshold (QT) implementation for liver shear wave elastography (SWE) in children during free breathing.Methods: The QT, which adjusts the SWE map display based on shear wave quality, was set at 55%. Phantom measurements (PMs) were taken with a fixed probe using QT (termed PM-1); a moving probe without QT (PM-2); and a moving probe with QT (PM-3). Each measurement was subjected to random samplings of various sizes. Clinical measurements (CMs) were obtained from children with biliary atresia using following protocols: CM-1, manually defined regions of interest (ROIs); CM-2, default ROIs without QT; and CM-3, default ROIs with QT. Elasticity measurements were compared across fibrosis grades, and color patterns on the SWE maps were analyzed.Results: In the phantom experiments, the moving probe produced lower elasticity measurements; this difference decreased upon QT application. With the moving probe, random sampling indicated fewer interquartile range-to-median ratios exceeding 30% upon QT application (4% vs. 14% when five values were sampled, P=0.004). In clinical experiments, QT improved the differentiation of fibrosis grade in patients over 5 years old, with a significant difference between moderate and severe fibrosis (P=0.004). Elasticity variability was positively correlated with fibrosis grade (τ=0.376, P<0.001). Certain apparent errors, termed artificial stripe patterns, were not eliminated by QT.Conclusion: Applying QT to exclude low-quality pixels can minimize measurement error and improve differentiation of liver fibrosis grades. The presence of an artificial stripe pattern on the SWE map may indicate images requiring exclusion.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

최근 본 자료

전체보기

댓글(0)

0