Tinh Le (Case Western Reserve University School of Medicine Cleveland OH USA) James Neuenschwander (Department of Emergency Medicine Genesis Healthcare System Zanesville OH USA) Parker Cordial (The Ohio State University College of Medicine Columbus OH USA) Mackenzie Sankoe (Ohio University Heritage College of Osteopathic Medicine Athens OH USA 5The Ohio State University) Ankur Parekh (The Ohio State University Columbus OH USA) Brian Hiestand (Department of Emergency Medicine Wake Forest School of Medicine Winston Salem NC USA) WF Peacock (Department of Emergency Medicine Baylor College of Medicine Houston TX USA)
저널정보
대한응급의학회 Clinical and Experimental Emergency Medicine Clinical and Experimental Emergency Medicine Vol.9 No.1
발행연도
2022.3
수록면
24 - 28 (5page)
DOI
10.15441/ceem.21.065

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Objective Remote cardiac implantable electronic device (CIED) interrogators, originally developed for home use, have been proven to be efficacious in clinical settings, especially emergency departments. Concern exists that attempting to interrogate a CIED with the remote interrogator of a different brand, i.e., a brand-mismatched interrogator, may cause device malfunction. The aim of this study was to determine if intentionally attempting to interrogate a CIED with a brand-mismatched remote interrogator resulted in device malfunction.Methods A total of 75 ex vivo CIEDs manufactured by various companies underwent attempted interrogation by a brand-mismatched remote interrogator. CIED settings were compared before and after attempted mismatch interrogation. A total of 30 in vivo CIEDs were then randomized for an attempted 2-minute mismatched remote interrogation by one of the two possible mismatched remote interrogators. CIED settings were compared before and after attempted mismatch interrogation.Results Of 150 ex vivo brand-mismatched interrogations, no device setting changes or malfunctions occurred; no remote interrogators connected to a mismatched CIED, and no devices were turned off. In the 30 patients undergoing brand-mismatched interrogations, the mean (standard deviation) age was 71.6 ( ± 14.7) years, 16 (53%) were male, with 24 pacemakers (80%), four pacemaker/implantable cardioverter defibrillators (13%), and two implantable cardioverter defibrillators (7%). Of the 30 mismatched interrogations performed, no device setting changes or malfunctions occurred; no remote interrogators connected to a mismatched CIED, and no devices turned off.Conclusion In a total 180 attempted brand-mismatched CIED interrogations, no CIED malfunctions occurred. This suggests that the use of remote CIED interrogators when device manufacturer is unknown is unlikely to result in adverse CIED-related events.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0