메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
So-Ryoung Lee (Seoul National University Hospital) Ji Hyun Lee (Seoul National University Bundang Hospital) Eue-Keun Choi (Seoul National University Hospital) Eun-Kyung Jung (Medtronic Korea, Ltd.) So-Jeong You (Medtronic Korea, Ltd.) Seil Oh (Seoul National University Hospital) Gregory YH Lip (Seoul National University Hospital)
저널정보
대한심장학회 Korean Circulation Journal Korean Circulation Journal Vol.54 No.1
발행연도
2024.1
수록면
13 - 27 (15page)
DOI
https://doi.org/10.4070/kcj.2023.0084

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background and Objectives: Comprehensive epidemiological data are lacking on the incident atrial fibrillation (AF) in patients with cardiac implantable electronic devices (CIEDs). This study aimed to examine the incidence, risk factors, and AF-related adverse outcomes of patients with CIEDs. Methods: This was an observational cohort study that analyzed patients without prevalent AF who underwent CIED implantation in 2009–2018 using a Korean nationwide claims database. The subjects were divided into three groups by CIED type and indication: pacemaker (n=21,438), implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy (CRT) with heart failure (HF) (n=3,450), and ICD for secondary prevention without HF (n=2,146). The incidence of AF, AF-associated predictors, and adverse outcomes were evaluated. Results: During follow-up, the incidence of AF was 4.3, 7.3, and 5.1 per 100 person-years in the pacemaker, ICD/CRT with HF, and ICD without HF cohorts, respectively. Across the three cohorts, older age and valvular heart disease were commonly associated with incident AF. Incident AF was consistently associated with an increased risk of ischemic stroke (3.8–11.4-fold), admission for HF (2.6–10.5-fold), hospitalization for any cause (2.4–2.7-fold), all-cause death (4.1–5.0-fold), and composite outcomes (3.4–5.7-fold). Oral anticoagulation rates were suboptimal in patients with incident AF (pacemaker, 51.3%; ICD/CRT with HF, 51.7%; and ICD without HF, 33.8%, respectively). Conclusions: A substantial proportion of patients implanted CIED developed newly diagnosed AF. Incident AF was associated with a higher risk of adverse events. The importance of awareness, early detection, and appropriate management of AF in patients with CIED should be emphasized.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

최근 본 자료

전체보기

댓글(0)

0