Yoon Sumi (Department of Laboratory Medicine Chung-Ang University College of Medicine Seoul Korea) Moon Hee-Won (Department of Laboratory Medicine Konkuk University School of Medicine Seoul Korea) Kim Hanah (Department of Laboratory Medicine Konkuk University School of Medicine Seoul Korea) Hur Mina (Department of Laboratory Medicine Konkuk University School of Medicine Seoul Korea) Yun Yeo-Min (Department of Laboratory Medicine Konkuk University School of Medicine Seoul Korea)
저널정보
대한진단검사의학회 Annals of Laboratory Medicine Annals of Laboratory Medicine 제42권 제1호
발행연도
2022.1
수록면
63 - 70 (8page)
DOI
10.3343/alm.2022.42.1.63

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: Recently, two fully automated immunoassays for antinuclear antibody (ANA) screening were introduced: EliA CTD Screen (Thermo Fisher Scientific, Freiburg, Germany) and QUANTA Flash CTD Screen Plus (Inova Diagnostics, San Diego, USA). We evaluated their clinical performance in comparison with the indirect immunofluorescence assay (IIFA) and analyzed samples with discrepant results. Methods: In total, 406 serum samples (206 from patients undergoing routine checkups and 200 from rheumatology clinic patients) were assayed using EliA, QUANTA Flash, and IIFA. We evaluated assay concordance and agreement and confirmed the presence of anti-extractable nuclear antigen (ENA) antibodies in samples with discrepant automated immunoassay and IIFA results. Additionally, we compared the clinical performance of each assay in diagnosing ANA-associated rheumatic disease (AARD) and adjusted the cut-off values. Results: In rheumatology clinic samples, the concordance and agreement were 91.5% and strong between EliA and QUANTA Flash, 79.0% and weak between EliA and IIFA, and 80.5% and moderate between QUANTA Flash and IIFA, respectively. In automated immunoassay-positive, IIFA-negative samples (N=15), all anti-ENA antibodies detected (6/15) were anti-Sjogren’s syndrome antigen A/Ro (Ro60) antibodies. The automated immunoassays and IIFA showed high accuracy for diagnosing AARD, and adjusted cut-off values improved their sensitivities (EliA with 0.56 ratio, 82.9% sensitivity; QUANTA Flash with 9.7 chemiluminescent units, 87.8% sensitivity). Conclusions: The two automated immunoassays showed reliable performance compared with IIFA and can be efficiently used with the IIFA in clinical immunology laboratories. Clinical cut-off values can be adjusted according to the workflow in each laboratory.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0