메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
김꽃송이 (건축공간연구원) 강현미 (건축공간연구원) 김충호 (서울시립대)
저널정보
대한건축학회 대한건축학회논문집 大韓建築學會論文集 第39卷 第2號(通卷 第412號)
발행연도
2023.2
수록면
3 - 14 (12page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
The purpose of this study is to present indicators of facilities planning element(FPE) and maintenance system(MS) to determine the fire safety level of a sanatorium for senior citizens. This research focused on deriving indicators scientifically proven in previous studies according to the Evidence Based Design theory. The indicators were specifically derived through a two-step process of derivation of primary indicators through Systematic Literature Reviews (SLR) and verification of indicators through Focus Group Interviews (FGI). As a result, most of the indicators derived through the SLR and FGI were mutually consistent. It was found that the FPE indicators were more effective for fire safety than the MS. The most effective FPE indicators for fire safety were sprinklers and escape and rescue equipment. In addition, smoke exhaust facilities, automatic fire detection systems, fireproof partitions, fire extinguishers, and single alarm detectors were also shown as major indicators. Among MS indicators, fire drill, in-house inspection on fire-fighting systems, fire evacuation manual, and the preparation of an evacuation plan was found to be important indicators. It was also found that securing sufficient staff is essential to ensure the safety of elderly with weak physical and cognitive characteristics. On the other hand, the importance of sprinklers and escape and rescue equipment for fire safety was found to be different in terms of derivation of indicators according to SLR and FGI. From this point of view, it is necessary to investigate whether smoke exhaust facilities, automatic fire detection systems, single alarm detectors, fireproof partitions, and fire extinguishers were installed to improve the fire safety of elderly care facilities. Lastly, this study presented a list of data that should be collected to understand the fire safety level of sanatoriums for senior citizens.

목차

Abstract
1. 서론
2. 문헌고찰
3. 근거기반설계와 체계적 문헌조사
4. 노인요양시설 화재안전 수준 분석을 위한 시설 계획요소 및 유지관리제도 지표 도출
5. 요약 및 결론
REFERENCES

참고문헌 (37)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2023-540-000456090