메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Kumail Hassan Kharal (Yeungnam University) Chang-Hwan Kim (Yeungnam University) Tahir Khurshaid (Yeungnam University) Sang-Bong Rhee (Yeungnam University)
저널정보
한국조명·전기설비학회 조명·전기설비학회논문지 조명·전기설비학회논문지 제31권 제10호
발행연도
2017.10
수록면
60 - 67 (8page)
DOI
10.5207/JIEIE.2017.31.10.060

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Load management and electricity theft on the distribution side are one of the major problems of electrical power systems. This paper presents a novel technique used to eradicate load management and electricity theft detection problems by designing a working model named “Distribution Side Load Monitoring, Control and Theft Detection”. This model consists of three modules: Main module, Consumer module and Relay module. A microcontroller ‘ATmega8’ is the main part of these modules. The Proteus Design Suite was used for the simulation and printed circuit board layout. The main module is installed in a substation and has voltage and current sensors that measure the voltage and current of the line that is connected to the consumer through relays. This limits the consumer’s power and detects theft. This module is also connected to a computer through parallel interface. A consumer module is installed in the energy meter. This module measures and monitors load power. A relay module is simply a switching circuit between the main module and consumer module that can turn on or off the consumer supply on main module instructions. The consumer system (consumer module) installed on the electric meter will send its consumption readings to the central server (substation module) for processing and bill computing. The central server (substation module) will also measure the total power being distributed to all consumers. The difference between the two readings must ideally be zero, when no illegal user is attempting to tap power lines assuming the line losses are known. An illegal load in the power line will cause a difference in the distribution and consumption readings. This difference in the two readings warns the power station of the theft status for that power line and accordingly a manual or auto control mechanism is implemented. The effectiveness of this work has been tested on Proteus Design Suite software.

목차

Abstract
1. Introduction
2. System description and analysis
3. Physical implementation
4. Conclusions
References

참고문헌 (7)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0