메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Sean WY Lee (Yong Loo Lin School of Medicine National University of Singapore Singapore) Clara Lee Ying Ngoh (Department of Medicine National University Health System Singapore) Horng Ruey Chua (National University Health System Singapore) Sabrina Haroon (National University Health System Singapore) Weng Kin Wong (National University Health System Singapore) Evan JC Lee (National University Health System Singapore) Titus WL Lau (National University Health System Singapore) Sunil Sethi (Department of Pathology National University Health System Singapore) Boon Wee Teo (Yong Loo Lin School of Medicine National University of Singapore Singapore)
저널정보
대한신장학회 Kidney Research and Clinical Practice Kidney Research and Clinical Practice Vol.38 No.1
발행연도
2019.1
수록면
71 - 80 (10page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: Chronic kidney disease (CKD) is associated with fluid retention, which increases total body water (TBW) and leads to changes in intracellular water (ICW) and extracellular water (ECW). This complicates accurate assessments of body composition. Analysis of bioelectrical impedance may improve the accuracy of evaluation in CKD patients and multiple machines and technologies are available. We compared body composition by bioimpedance spectroscopy (BIS) against multi-frequency bioimpedance analysis (BIA) in a multi-ethnic Asian population of stable, non-dialysis CKD patients. Methods: We recruited 98 stable CKD patients comprising 54.1% men and 70.4% Chinese, 9.2% Malay, 13.3% Indian, and 8.2% other ethnicities. Stability was defined as no variation in serum creatinine > 20% over three months. Patients underwent BIS analyses using a Fresenius body composition monitor, while BIA analyses employed a Bodystat Quadscan 4000. Results: Mean TBW values by BIS and BIA were 33.6 ± 7.2 L and 38.3 ± 7.4 L; mean ECW values were 15.8 ± 3.2 L and 16.9 ± 2.7 L; and mean ICW values were 17.9 ± 4.3 L and 21.0 ± 4.9 L, respectively. Mean differences for TBW were 4.6 ± 1.9 L (P < 0.001), for ECW they were 1.2 ± 0.5 L (P < 0.001), and for ICW they were 3.2 ±1.8 L (P < 0.001). BIA and BIS measurements were highly correlated: TBW r = 0.970, ECW r = 0.994, and ICW r = 0.926. Compared with BIA, BIS assessments of fluid overload appeared to be more associated with biochemical and clinical indicators. Conclusion: Although both BIA and BIS can be used for body water assessment, clinicians should be aware of biases that exist between bioimpedance techniques. The values of body water assessments in our study were higher in BIA than in BIS. Ethnicity, sex, body mass index, and estimated glomerular filtration rate were associated with these biases.

목차

등록된 정보가 없습니다.

참고문헌 (33)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0