메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Young Jin Youn (Yonsei University) Sang-Yong Yoo (University of Ulsan) Jun-Won Lee (Yonsei University) Sung-Gyun Ahn (Yonsei University) Seung-Hwan Lee (Yonsei University) Junghan Yoon (Yonsei University) Jae Hyoung Park (Korea University) Woong Gil Choi (Konkuk University) Sungsoo Cho (Dankook University) Sang-Wook Lim (CHA Bundang Medical Center) Yang Soo Jang (Ewha Womans University) Ki Hwan Kwon (Hallym University) 이남호 (한림대학교) Joon Hyung Doh (Gachon University) Woong Chol Kang (Yonsei University) Dong Woon Jeon (National Health Insurance Service Ilsan Hospital) Bong-Ki Lee (Kangwon National University) Jung Ho Heo (Kosin University) Bum-KeeHong (Yonsei University) Hyun-Hee Choi (Hallym University)
저널정보
대한심장학회 Korean Circulation Journal Korean Circulation Journal Vol.50 No.4
발행연도
2020.1
수록면
317 - 327 (11page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background and Objectives: Recently, Genoss drug-eluting stent (DES)™ stent comprising cobalt-chromium platform with an ultrathin strut thickness, sirolimus, and an abluminal biodegradable polymer was developed. Owing to the lack of substantial evidence for the safety and efficacy of this stent, we report 12-month results of the Genoss DES™ stent. Methods: We analyzed subjects who were eligible for a 12-month follow-up from the ongoing Genoss DES™ registry, which is a prospective, single-arm, observational, multicenter trial to investigate the clinical outcomes after the successful Genoss DES™ stent implantation among all-comers. The primary endpoint was a device-oriented composite outcome, defined as cardiac death, target vessel-related myocardial infarction, and target lesion revascularization at 12-month follow-up. Results: Among 622 subjects, the mean age of subjects was 66.5±10.4 years, 70.6% were males, 67.5% had hypertension, and 38.3% had diabetes. The implanted stent number, diameter, and length per patient were 1.5±0.8, 3.1±0.4 mm, and 36.0±23.3 mm, respectively. At 12-month clinical follow-up, the primary endpoint occurred only in 4 (0.6%) subjects. Conclusions: The novel Genoss DES™ stent exhibited excellent safety and efficacy in real-world practice.

목차

등록된 정보가 없습니다.

참고문헌 (19)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0