메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
홍주연 (연세대학교 의과대학 산업보건연구소) 김치년 (연세대학교 의과대학 산업보건연구소) 정재훈 (연세대학교 의과대학 산업보건연구소) 장정환 (연세대학교 의과대학 산업보건연구소) 노재훈 (연세대학교 보건대학원 산업보건학과)
저널정보
한국산업보건학회 (구 한국산업위생학회) 한국산업보건학회지 한국산업보건학회지 제9권 제1호
발행연도
1999.1
수록면
23 - 40 (18page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
The analysis of thiodiglycolic acid in urine has been used as an index of biological exposure to vinyl chloride. Unfortunately thiodiglycolic acid has a strong hydrophilic character, because it has two carboxylic groups, so that it can only be extracted with organic solvent with a great difficulty. Underivatized thiodiglycolic acid tends to tail because of non-specific interaction with the inert support. Therefore, esterification is the obvious first choice for derivatization of thiodiglycolic acid, particularly for gas chromatography. In this study, the focus of interest is to compare two method of esterifications (methylation and silylation). Methylation is to make the methyl ester of thiodiglycolic acid by reaction with diazomethane. Silylation is to make the trimethylsilyl ester of thiodiglycolic acid by reaction with N-trimethylsily-ldiethylamine. The results and conclusions are as the following: 1. The detection limit (sensitivity) of methylated thiodiglycolic acid was $5.00{\mu}g/m{\ell}$ and silylated thiodiglycolic acid was $3.07{\mu}g/m{\ell}$ by gas chromatography with flame ionization detector. 2. The optimal liquid-liquid extraction of thiodiglycolic acid was as following: To each of the tubes, $15m{\ell}$ of urine, concentrated sulfuric acid (pH 1 - 2) and 5 gsodium sulfate were added. The samples was extracted three times with $5m{\ell}$ ethylacetate each time. 3. The methylated thiodiglycolic acid was more stable than silylated thiodiglycolic acid in extractional solvent which contained humidity. 4. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.07324 in methylated thiodiglycolic acid with external standard calibration, and 0.07033 in methylated thiodiglycolic acid with internal standard calibration. 5. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.10914 in silylated thiodiglycolic acid with external standard calibration, and 0.13602 in silylated thiodiglycolic acid with internal standard calibration. From the above results, the analysis of methylated thiodiglycolic acid was more sensitive (limit of detection) than silylated thiodiglycolic acid by gas chromatography. However, the methylated thiodiglycolic acid was stable in the humidity and was separated sharply on chromatogram. Also, analysis of methylated thiodiglycolic acid was more precise (pooled coefficient of variation for 4 days) than silylated thiodiglycolic acid. In conclusion, it is established that the analysis of methylated thiodiglycolic acid is appropriate for biological monitoring of exposure to vinyl chloride.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0