메뉴 건너뛰기
Library Notice
Institutional Access
If you certify, you can access the articles for free.
Check out your institutions.
ex)Hankuk University, Nuri Motors
Log in Register Help KOR
Subject

Cryoballoon Catheter Ablation in Korean Patients With Paroxysmal and Persistent Atrial Fibrillation: One Year Outcome From the Cryo Global Registry
Recommendations
Search

논문 기본 정보

Type
Academic journal
Author
Hong Euy Lim (Hallym University Sacred Heart Hospital) Il-Young Oh (Seoul National University Bundang Hospital) Fred J Kueffer (Medtronic) Kelly Anna van Bragt (Medtronic) Young Keun On (Samsung Medical Center)
Journal
The Korean Society of Cardiology Korean Circulation Journal Korean Circulation Journal Vol.52 No.10 KCI Accredited Journals
Published
2022.10
Pages
755 - 767 (13page)
DOI
https://doi.org/10.4070/kcj.2022.0127

Usage

cover
Cryoballoon Catheter Ablation in Korean Patients With Paroxysmal and Persistent Atrial Fibrillation: One Year Outcome From the Cryo Global Registry
Ask AI
Recommendations
Search

Abstract· Keywords

Report Errors
Background and Objectives: Cryoballoon catheter ablation for the treatment of patients with symptomatic atrial fibrillation (AF) has been adopted globally, but there are limited multicenter reports of 12-month outcomes in the Korean patient population. This analysis evaluated the clinical performance and safety of cryoballoon ablation (CBA) according to standard-of-care practices in Korea. Methods: This evaluation of Korean patients with AF was conducted within the larger Cryo Global Registry, which is a prospective, multicenter, post-market registry. Freedom from a ≥30-second recurrence of atrial arrhythmias (after a 90-day blanking period until 12 months) and procedural safety were examined in subjects treated with CBA at 3 Korean centers. Results: Overall, 299 patients with AF (60±11 years old, 24.7% female, 50.5% paroxysmal AF) underwent CBA using the Arctic Front Advance cryoballoon. Of those, 298 were followed-up for at least 12 months. Mean procedure-, left atrial dwell- and fluoroscopy time was 76±21 minutes, 56±23 minutes, and 27±23 minutes, respectively. Freedom from AF recurrence at 12 months was 83.9% (95% confidence interval [CI], 76.9–88.9%) in the paroxysmal and 61.6% (95% CI, 53.1–69.0%) in the persistent AF cohort. Rhythm monitoring was performed on average 4.7±1.4 times during the follow-up period. Serious device- or procedure-related adverse events occurred in 2 patients (0.7%). The 12-month Kaplan-Meier estimate of freedom from repeat ablation and cardiovascular-related hospitalization was 93.8% (95% CI, 90.4–96.1%) and 89.7% (95% CI, 85.6–92.7%), respectively. Conclusions: CBA is an efficient, effective, and safe procedure for the treatment of AF patients when used according to real-world practices in Korea.

Contents

No content found

References (0)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Recently viewed articles

Comments(0)

0

Write first comments.