Fontenele, Rocharles C. (Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas[UNICAMP]) Nascimento, Eduarda H.L. (Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas[UNICAMP]) Santaella, Gustavo M. (Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas[UNICAMP]) Freitas, Deborah Queiroz (Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas[UNICAMP])
저널정보
대한영상치의학회 Imaging science in dentistry Imaging science in dentistry 제50권 제1호
발행연도
2020.1
수록면
23 - 30 (8page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Purpose: This study was conducted to assess the effectiveness of a metal artifact reduction (MAR) algorithm activated at different times during cone-beam computed tomography (CBCT) acquisition on the magnitude of artifacts generated by a zirconium implant. Materials and Methods: Volumes were obtained with and without a zirconium implant in a human mandible, using the OP300 Maxio unit. Three modes were tested: without MAR, with MAR activated after acquisition, and with MAR activated before acquisition. Artifacts were assessed in terms of the standard deviation (SD) of gray values and the contrast-to-noise ratio (CNR) in 6 regions of interest with different distances (10 to 35 mm, from the nearest to the farthest) and angulations(70° to 135°) from the implant region. Results: In the acquisitions without MAR, the regions closer to the implant(10 and 15mm) had a higher SD and lower CNR than the farther regions. When MAR was activated (before or after), SD values did not differ among the regions (P>0.05). The region closest to the implant presented a significantly lower CNR in the acquisitions without MAR than when MAR was activated after the acquisition; however, activating MAR before the acquisition did not yield significant differences from either of the other conditions. Conclusion: Both modes of MAR activation were effective in decreasing the magnitude of CBCT artifacts, especially when the effects of the artifacts were more noticeable.

목차

등록된 정보가 없습니다.

참고문헌 (22)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0