메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Musammad Rashida Begum (The Royal London Hospital) Rory Cuthbert (The Royal London Hospital) Cameron Andrew Joseph Dott (The Royal London Hospital) Owen O’Neill (The Royal London Hospital) Mohammed Tahir (The Royal London Hospital) Adrian Carlos (The Royal London Hospital) Livio Di Mascio (The Royal London Hospital)
저널정보
대한견주관절의학회 대한견주관절의학회지 대한견주관절의학회지 제28권 제1호
발행연도
2025.3
수록면
3 - 8 (6page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Background: Iatrogenic suprascapular nerve injury secondary to posterior drilling or screw penetration is a recognized complication of bone block or coracoid process transfers for anterior glenohumeral instability. We present the first cadaveric study that assesses the safety of posteroanterior reference guides and quantifies the relationship of the suprascapular nerve to posterior glenoid fixation with suture buttons.
Methods: Anterior glenoid bone block reconstruction with suture buttons utilizing a posteroanterior reference guide was performed in 10 fresh frozen cadavers via a posterior portal. Bullets were inserted in predefined superior and inferior guide holes via percutaneous incisions to facilitate posteroanterior drilling. Looped guide wires were used to deliver suture buttons from anterior to posterior positions. The shoul-der joint was disarticulated and the infraspinatus sharply elevated until the suprascapular nerve was visualized. Four independent static measures of the shortest distance from the superior drill sleeve to the lateral aspect of the suprascapular nerve were recorded.
Results: The suprascapular nerve was not compromised utilizing the posteroanterior guide and suture button fixation technique in any specimen. The mean distance from superior sleeve tunnel to the suprascapular nerve was 5.00 mm (range, 3.25–8.00 mm) in females and 6.80 mm (range, 5.50–8.75 mm) in males. The shortest distance was 3.25 mm and the longest was 8.75 mm.
Conclusions: The use of posteroanterior reference guides for suture button fixation was not associated with iatrogenic suprascapular nerve injury in the specimens examined. However, the proximity of the suprascapular nerve underscores the need for caution. Comparative analysis with anteroposterior bone block techniques is required to establish the potential benefits of this procedure.

목차

INTRODUCTION
METHODS
RESULTS
DISCUSSION
CONCLUSIONS
REFERENCES

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-151-25-02-092499869