메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Maxime Berthelot‑Richer (Department of Cardiology, Hôpital du Sacré-Coeur de Montréal, University of Montreal) Halyna Viktorivna Vakulenko (Department of Cardiology, Hôpital du Sacré-Coeur de Montréal, University of Montreal) Anna Calleja (Division of Cardiology, Toronto General Hospital, University of Toronto) Anna Woo (Division of Cardiology, Toronto General Hospital, University of Toronto) Paaladinesh Thavendiranathan (Division of Cardiology, Toronto General Hospital, University of Toronto) Frédéric Poulin (Department of Cardiology, Hôpital du Sacré-Coeur de Montréal, University of Montreal)
저널정보
한국심초음파학회 Journal of Cardiovascular Imaging Journal of Cardiovascular Imaging 제32권
발행연도
2024.6
수록면
2 - 2 (1page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background Mitral annulus (MA) area is derived during transthoracic echocardiography (TTE) assuming of a circular shape using the MA diameter from the apical 4 chamber (A4c) view. Since the MA is not a circular structure, we hypothesized that an elliptical model using parasternal long-axis (PLAX) and apical 2 chamber (A2c) view measured MA diameters would have better agreement with 3-dimensional transesophageal echocardiography (3D TEE) measured MA in degenerative mitral valve disease (DMVD). Methods Seventy-six patients with moderate-to-severe DMVD had 2D TTE and 3D TEE performed. MA area was measured retrospectively using semi-automatic modeling of 3D data (3D TEEsa) and considered as the reference method. MA diameters were measured using different 2D TTE views. MA area was calculated using assumptions of a circular or an elliptical shape. 2D TTE derived and 3D TEEsa. MA areas were compared using linear regression and Bland-Altman analysis. Results The median MA area measured at 3D TEEsa was 1,386 (1,293–1,673) mm2. With 2D TTE, the circular model using A4c view diameter resulted in a small systematic underestimation of MA area (6%), while the elliptical model using PLAX and A2c diameters resulted in 25% systematic underestimation. The standard deviations of the distributions of inter-method differences were wide for all 2D TTE methods (265–289 mm2) when compared to 3D TEEsa, indicating imprecision. Conclusions When compared with 3D TEEsa modeling of the MA as the reference, the assumption of a circular shape using A4c TTE view diameter was the method with the least systematic error to assess MA area in DMVD and moderate to severe regurgitation.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

최근 본 자료

전체보기

댓글(0)

0