메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
김계환 (충남대학교) 정경진 ((의료)길의료재단)
저널정보
대한배뇨장애요실금학회 International Neurourology Journal International Neurourology Journal 제27권
발행연도
2023.5
수록면
34 - 39 (6page)
DOI
10.5213/inj.2346098.049

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Purpose: Foley catheter (FC) insertion is very basic yet one of the most widely performed procedures all across the fields of medicine. Since FC was first introduced in 19020’s, no significant improvement has been made in view of methodology, despite the inconvenience associated with cumbersome preparation, procedure, and the patients’ discomfort with having to have their genitalia exposed. We developed a new, easy-to-use FC insertion device, Quick Foley, that provides an innovative approach to introducing FC while simplifying and minimizing time spent without compromising the sterility. Methods: We developed an all-in-one disposable FC introducer contains all the necessary components in a single-device-kit. Minimal plastic components are necessary to keep accuracy and consistency, but the rest are made of the paper to minimize plastic waste. The preparation is done by connecting to the drainage bag, spurring the lubricant gel through gel insert, separat ing the tract, and connecting with the ballooning syringe. For the insertion, after sterilizing the urethral orifice, rotate the con trol knob to feed FC to the end of the urethra. After ballooning, dissembling of the device is done only by opening and remov ing the module, then only the FC remains. Results: As the device is all-in-one, there is no need to prearrange the FC tray, simplifies the FC preparation and catheteriza tion procedure. This device not only makes it convenient for the practitioner, but ultimately, it will reduce the psychological discomfort experienced by patient by truncating perineal exposure time. Conclusions: We have successfully developed a novel device that reduces the cost and burden of using FC for practitioners while maintaining an aseptic technique. Furthermore, this all-in-one device allows the entire procedure to be completed much more quickly compared to the current method, so this minimizes perineal exposure time. Both practitioners and patients can benefit by this new device.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0