Youn Sung Won (Department of Radiology Catholic University of Daegu Medical Center School of Medicine Catholic Uni) Kwon Juyoung (Department of Biomedical Engineering School of Medicine Kyungpook National University Daegu Korea.) Kim Junghoon (Department of Biomedical Engineering School of Medicine Kyungpook National University Daegu Korea.) Park Jieun (Department of Biomedical Engineering School of Medicine Kyungpook National University Daegu Korea.) Ahn Dohyun (Department of Biomedical Engineering School of Medicine Kyungpook National University Daegu Korea.) Lee Jongmin (Department of Biomedical Engineering School of Medicine Kyungpook National University Daegu Korea.D)
저널정보
아시아심장혈관영상의학회 Cardiovascular Imaging Asia Cardiovascular Imaging Asia Vol.3 No.2
발행연도
2019.4
수록면
35 - 46 (12page)
DOI
10.22468/cvia.2018.00248

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Objective: This study sought to explore the novel use of artificial neural networks (ANNs) to develop a contrast-enhanced computed tomography (CT) angiographic (CECTA) protocol based on ideal bolus geometry. Materials and Methods: An aortic phantom connected to a closed-circuit pulsatile flow system was developed to simulate the bolus geometry of the human abdominal aorta. A total of 135 CECTA datasets were obtained using a 16-row multidetector CT scanner, and timeenhancement curves (TECs) were generated using varying input conditions including heart rate (HR), iodine delivery rate (IDR) and concentration (IC), and tube potential (kVP). Time points and density values including peak enhancement (PE) and time-to-peak (TTP) were assessed as a function of injection and scan protocols. Statistical analysis was performed using correlation and linear regression analyses. By using data from phantom experiments, machine learning produced networks between four input (HR, IC, IDR, and kilovoltage) and five output [TTP?time-to-foot (TTF), PE, (PE)/(TTP?TTF), maximal-upslope-gradient (MUG), and peakplateau- length (PPL)] conditions. The bolus geometry index was defined as (TTP?TTF)/Σ(PE, (PE)/(TTP?TTF), MUG, PPL). The lowest bolus geometry index value was considered ideal in ANN testing. Results: The geometric changes on TECs were observed based on changes in HR, IDR, IC, and kilovoltage value. PE was closely related to IDR (B=17.471) and kVp (B=-0.208) (corrected R2=0.919; all p<0.001). TTF, TTP, and PPL were related to HR and IDR, respectively. HR and IDR remained contributing factors after multiple linear regression analysis (corrected R2=0.901, 0.815, and 0.363; all p<0.001). Among 39690 total datasets produced following ANN training, the combination of IC, HR, tube potential, and IDR in the 38010th dataset resulted in the lowest bolus geometry index. Tables of input variables are presented after modification to clinically acceptable ranges. Conclusion: ANN of phantom experiments showed the potential to determine optimal CECTA parameters for ideal bolus geometry individualized for each subject.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0