메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Bhavina Patel (Sardar Vallabhbhai National Institute of Technology) Hiren Patel (Sardar Vallabhbhai National Institute of Technology) Pragna Vachhrajani (SMIMER) Divyang Shah (SMIMER) Alpesh Sarvaia (U. N. Mehta Institute of Cardiology and Research)
저널정보
대한의용생체공학회 Biomedical Engineering Letters (BMEL) Biomedical Engineering Letters (BMEL) Vol.9 No.1
발행연도
2019.1
수록면
127 - 144 (18page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Anesthetic agent propofol needs to be administered at an appropriate rate to prevent hypotension and postoperative adversereactions. To comprehend more suitable anesthetic drug rate during surgery is a crucial aspect. The main objective of thisproposal is to design robust automated control system that work effi ciently in most of the patients with smooth BIS andminimum variations of propofol during surgery to avoid adverse post reactions and instability of anesthetic parameters. And also, to design advanced computer control system that improves the health of patient with short recovery time and lessclinical expenditures. Unlike existing research work, this system administrates propofol as a hypnotic drug to regulate BIS,with fast bolus infusion in induction phase and slow continuous infusion in maintenance phase of anesthesia. The novelty ofthe paper lies in possibility to simplify the drug sensitivity-based adaption with infusion delay approach to achieve closedloopcontrol of hypnosis during surgery. Proposed work uses a brain concentration as a feedback signal in place of the BISsignal. Regression model based estimated sensitivity parameters are used for adaption to avoid BIS signal based frequentadaption procedure and large off set error. Adaptive smith predictor with lead–lag fi lter approach is applied on 22 diff erentpatients’ model identifi ed by actual clinical data. The actual BIS and propofol infusion signals recorded during clinical trialswere used to estimate patient’s sensitivity parameters EC 50 and λ . Simulation results indicate that patient’s drug sensitivityparameters based adaptive strategy facilitates optimal controller performance in most of the patients. Results are obtainedwith proposed scheme having less settling time, BIS oscillations and small off set error leads to adequate depth of anesthesia. A comparison with manual control mode and previously reported system shows that proposed system achieves reductionin the total variations of the propofol dose. Proposed adaptive scheme provides better performance with less oscillation inspite of computation delay, surgical stimulations and patient variability. Proposed scheme also provides improvement inrobustness and may be suitable for clinical practices.

목차

등록된 정보가 없습니다.

참고문헌 (42)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0