메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
김용옥 (한국인삼연초연구원) 이경구 (한국인삼연초연구원) 장기철 (한국인삼연초연구원) 김기환 (한국인삼연초연구원)
저널정보
한국연초학회 한국연초학회지 한국연초학회지 제20권 제2호
발행연도
1998.1
수록면
183 - 190 (8page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

이 논문의 연구 히스토리 (6)

초록· 키워드

오류제보하기
This study was conducted to analyze chemical components in flue-cured tobacco using near infrared spectroscopy(NIRS). Samples were collected in '96 and '97 crop year and were scanned in the wavelengths of 400 ~ 2500 nm by near infrared analyzer(NIRSystem Co., Model 6500). Calibration equations were developed and then analyzed flue-cured samples by NIRS. The standard error of calibration(SEC) and performance (SEP) of '96 crop year samples between NIRS and standard laboratory analysis(SLA) were 0.18% and 0.24% for nicotine, 1.60% and 1.77% for total sugar, 0.13% and 0.15% for total nitrogen, 0.58% and 0.68% for crude ash, 0.23% and 0.28% for ether extracts, and 0.09% and 0.08% for chlorine, respectively. The coefficient of determination($R^2$) of calibration and prediction samples between NIRS and SLA of '96 crop year samples was 0.94~0.99 and 0.83~0.97 depending on chemical components, respectively. The SEC and SEP of '97 crop year samples were similar to those of '96 crop year samples. The SEP of '97 crop year samples which were analyzed using '96 calibration equation was 0.32 % for nicotine, 2.72% for total sugar, 0.14 % for total nitrogen, 1.00 % for crude ash, 0.48 for ether extracts and 0.17% for chlorine, respectively. The prediction result was more accurate when calibration and prediction samples were produced in the same crop year than those of the different crop year. The SEP of '96 and '97 crop year samples using calibration equation which was developed '96 plus '97 crop year samples was similar to that of '96 crop year samples using 96 calibration equation and that of '97 crop year samples using '97 calibration equation, respectively. The SEP of '97 crop year samples using calibration equation which was developed '96 plus '97 crop year samples was lower than that of '97 crop year samples analyzed by '96 calibration equation. To improve the analytical inaccuracy caused by the difference of crop year between calibration and prediction samples, we need to include the prediction sample spectra which are different from calibration sample spectra in recalibration sample spectra, and then develop recalibration equation. Although the analytical result using NIR is not as good as SLA, the chemical component analysis using NIR can apply to tobacco leaves, leaf process or tobacco manufacturing process which demand the rapid analytical result.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0