메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
구인서 (서울대학교 의과대학 내과학교실) 고창순 (서울대학교 의과대학 내과학교실) 이문호 (서울대학교 의과대학 내과학교실)
저널정보
대한핵의학회 대한핵의학회지 대한핵의학회지 제7권 제1호
발행연도
1973.1
수록면
15 - 29 (15page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

이 논문의 연구 히스토리 (4)

초록· 키워드

오류제보하기
To attain a simple and reliable method of evaluating the thyroid function the reliability of the clinical manifestation and the conventional thyroid function tests in diagnosing the hyperthyroidism was studied. The subjects included 184 patients with hyperthyroidism and 66 cases with euthyroidism, who were treated at the Thyroid Clinic, Seoul National University Hospital, from July 1971 through August 1972. The observed results were as follows: 1. In the cases of hyperthyroidism, 19% of the patients were male and 81% female; in the cases of euthyroidism, 7.6% of the patients were male and 92.4% female. The majority of the patients were in 2nd to 4th decades of their lives. 2. There were objective signs clearly manifested in hyperthyroidism which were rare or absent in the euthyroid state. These clinical signs included wide pulse pressure, tachycardia, systolic murmur, exophthalmos, tremor, and warm skin. In the hyperthyroid state 91.3% of the cases manifested two or more of the above signs, whereas in the euthyroid state no patients manifested any two of the above signs. 3. The most frequent complaints of the patients with thyroid disease were palpitation, weight loss, increased appetite, heat intolerance, perspiration, hunger feeling; nervousness, exertional dyspnea, etc. There was no clear difference in the incidence of the symptoms between hyperthyroidism and euthyroidism. 4. In the diagnosis of hyperthyroidism, the reliability of thyroid ?unction tests was as follows; $T_7$ was 92.4% reliable, $^{125}IT_3$ resin uptake rate 91.6% reliable, $^{131}I$ thyroid uptake rate in 24 hrs. 89.4% reliable, serum $T_4$ level 85.9% reliable and BMR 75.5% reliable. Therefore the careful observation of the clinical manifestation of the disease is a simple and reliable way of making a correct diagnosis of either hyperthyroidism or euthyroidism. 5. In hyperthyroidism there shows no correlationship between the results of the thyroid function test and clinical signs but a high BMR was associated with both tachycardia and systolic murmur.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0