Estimation of Welding Time and Width of Weld Joint Part of Polyethylene Pipes by Microwave Reflection
Recommendations
Search
Questions

마이크로파 반사에 의한 폴리에틸렌 배관 융착부의 너비와 융착시간 추정

논문 기본 정보

Type
Academic journal
Author
Jungseok Lee (한국표준과학연구원) Ki-Bok Kim (한국표준과학연구원) Hyungtaik Lim (앤스코) Taegyung Kim (앤스코) Byoung-Kwan Cho (충남대학교)
Journal
The Korean Society For Nondestructive Testing JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING Vol.37 No.3 KCI Accredited Journals
Published
2017.6
Pages
164 - 169 (6page)
DOI
10.7779/JKSNT.2017.37.3.164

Usage

cover
📌
Topic
📖
Background
🔬
Method
🏆
Result
Estimation of Welding Time and Width of Weld Joint Part of Polyethylene Pipes by Microwave Reflection
Ask AI
Recommendations
Search
Questions

Abstract· Keywords

Report Errors
In this study, a microwave reflection technique was used to detect an abnormal joint in a polyethylene pipe. The polyethylene pipe specimens were fabricated at different welding times; the outer diameter and length or the specimens were 350 mm and 245 mm, respectively. Experimental microwave equipment was organized to transmit and receive the microwave signals at the weld joint parts of polyethylene pipe specimens at frequencies ranging from 12.4 to 18 GHz. The abnormal joint of polyethylene pipe specimens could be fully separated at 13.1 GHz and a linear relationship between the width of bead at polyethylene pipe and microwave reflection signal was found. Consequently, non-contact evaluation of the weld joint part of polyethylene pipes can be possible using the proposed microwave reflection technique.

Contents

초록
Abstract
1. 서론
2. 마이크로파 반사신호의 크기
3. 실험장비 및 방법
4. 실험결과
5. 결론
References

References (13)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Frequently Viewed Together

Recently viewed articles

Comments(0)

0

Write first comments.

UCI(KEPA) : I410-ECN-0101-2018-530-000986921