메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Seok Hyeon Yun (University of Ulsan College of Medicine) Sang Jin Park (University of Ulsan College of Medicine) Chang Sun Sim (University of Ulsan College of Medicine) Joo Hyun Sung (University of Ulsan College of Medicine) Ahra Kim (Ulsan University Hospital) Jang Myeong Lee (University of Ulsan College of Engineering) Sang Hyun Lee (Ulsan Science High School) Jiho Lee (University of Ulsan College of Medicine)
저널정보
대한직업환경의학회 대한직업환경의학회지 대한직업환경의학회지 제29권 제4호
발행연도
2017.5
수록면
1 - 11 (11page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Background: Recently, noise coming from the neighborhood via floor wall has become a great social problem. The noise between the floors can be a cause of physical and psychological problems, and the different types of floor impact sound (FIS) may have the different effects on the human’s body and mind. The purpose of this study is to assess the responses of subjective feeling, task performance ability, cortisol and HRV for the various types of floor impact.
Methods: Ten men and 5 women were enrolled in our study, and the English listening test was performed under the twelve different types of FIS, which were made by the combinations of bang machine (B), tapping machine (T), impact ball (I) and sound-proof mattress (M). The 15 subjects were exposed to each FIS for about 3 min, and the subjective annoyance, performance ability (English listening test), cortisol level of urine/saliva and heart rate variability (HRV) were examined. The sound pressure level (SPL) and frequency of FIS were analyzed. Repeated-measures ANOVA, paired t-test, Wilcoxon signed rank test were performed for data analysis.
Results: The SPL of tappingmachine (T) was reduced with the soundproof mattress (M) by 3.9–7.3 dBA. Impact ball (I) was higher than other FIS in low frequency (31.5–125 ㎐) by 10 dBA, and tapping machine (T) was higher than other FIS in high frequency (2–4 k ㎐) by 10 dBA. The subjective annoyance is highest in the combination of bang machine and tapping machine (BT), and next in the tapping machine (T). The English listening score was also lowest in the BT, and next in T. The difference of salivary cortisol levels between various types of FIS was significant (p = 0.003). The change of HRV parameters by the change of FIS types was significant in some parameters, which were total power (TP) (p = 0.004), low frequency (LF) (p = 0.002) and high frequency (HF) (p= 0.011).
Conclusions: These results suggest that the human’s subjective and objective responses were different according to FIS types and those combinations.