Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings
Recommendations
Search
Questions

주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가

논문 기본 정보

Type
Academic journal
Author
Kim, Deok-Sung (쏠라테크) Kim, Beob-Jeon (한국토지주택공사) Shin U-Cheul (대전대학교)
Journal
The Korean Solar Energy Society Journal of the Korean Solar Energy Society Vol.37 No.2 KCI Accredited Journals
Published
2017.4
Pages
35 - 45 (11page)

Usage

cover
📌
Topic
📖
Background
🔬
Method
🏆
Result
Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings
Ask AI
Recommendations
Search
Questions

Research history (2)

  • Are you curious about the follow-up research of this article?
  • You can check more advanced research results through related academic papers or academic presentations.
  • Check the research history of this article

Abstract· Keywords

Report Errors
The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was –6.5 to 61.0°C for mounted modules, –6.0~73.9°C for semi-integrated modules and –5.5 to 88.9°C for integrated modules. The temperature loss of each installation type was –14.0 to 16.1%, –13.8 to 21.9%, and –13.6 to 28.5%, respectively.

Contents

Abstract
1. 서론
2. 주거용 태양광발전시스템의 설치유형
3. 실증주택의 태양광발전시스템
4. 실증주택의 태양광발전시스템 분석
5. 시뮬레이션을 통한 태양광발전시스템 성능분석
6. 결론
REFERENCES

References (8)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Frequently Viewed Together

Recently viewed articles

Comments(0)

0

Write first comments.