Sang Jin Park (University of Ulsan College of Medicine) Joo Hyun Sung (University of Ulsan College of Medicine) Chang Sun Sim (University of Ulsan College of Medicine) Seok Hyeon Yun (University of Ulsan College of Medicine) Jeong Han Yeom (University of Ulsan College of Medicine) Joong-Keun Kwon (University of Ulsan College of Medicine) Jiho Lee (University of Ulsan College of Medicine)
저널정보
대한직업환경의학회 대한직업환경의학회지 대한직업환경의학회지 제28권 제9호
발행연도
2016.9
수록면
121 - 129 (9page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Background: The purpose of this study was to investigate hearing threshold changes of workers with unilateral conductive hearing loss who were exposed to workplace noise for 8-years.
Methods: Among 1819 workers at a shipyard in Ulsan, 78 subjects with an air-bone gap ≥10 ㏈HL in unilateral ears were selected. Factors that could affect hearing were acquired from questionnaires, physical examinations, and biochemistry examinations. Paired t-test was conducted to compare the hearing threshold changes over time between conductive hearing loss (CHL) ear and sensorineural hearing loss (SNHL) ear.
Results: The study included male subjects aged 48.7 ± 2.9, having worked for 29.8 ± 2.7 years. Hearing thresholds increased significantly in CHL ears and SNHL ears at all frequencies (0.5–6 ㎑) during follow-up period (p < 0.05). The threshold change at 4 ㎑ was 3.2 ㏈HL higher in SNHL ears which was statistically significant (p < 0.05). When workers were exposed to noise levels of 85 ㏈A and above, threshold change at 4 ㎑ was 5.6 ㏈HL higher in SNHL ears which was statistically significant (p < 0.05). Among workers aged below 50, the threshold change values were lower in low-frequency (0.5–2 ㎑) in SNHL ears, with a small range of changes, whereas in high-frequency (3–6 ㎑), the range of changes was greater SNHL ears (p < 0.05). Among workers aged 50 and above, SNHL ears showed a wider range of changes in both high- and low-frequency areas (p < 0.05).
Conclusions: At high-frequencies, particularly at 4 ㎑, the range of hearing threshold changes was lower in ears with conductive hearing loss than in contralateral ears. This is suggested as a protective effect against noise exposure.