A PLL with an unipolar charge pump and loop filter consisted of Sample-Hold capacitor and 2nd-order RC filter has been proposed. One advantage of the proposed PLL is that the charge pump mismatch problem associated with the conventional architecture is eliminated. It has been designed with a 1.8V 0.8㎛ CMOS process and proved by HSPICE simulation.