A low-rise steel-framed house has been developed as a construction pattern at domestic residential construction from the late of 1990. The major structural elements such as load-bearing walls and floor-assemble were made up of light-gauge steel around 1.0㎜ in thickness and light weight construction materials such as gypsum board, plywood and etc. Now the steel framed systems built with light-gauge steel and light-weight construction material have been trying to develop a new application such as the low rise apartments or building below 4 stories and the likes. In order to meet the building regulation in aspects of fire resistance of the above mentioned buildings the development of a proper fire resistance systems should be requested. For the satisfaction of building regulation in terms of fire resistance and to support of the safer structural elements such as load bearing walls and floor-ceiling assemblies in fire, we have conducted heat transfer analysis and fire resistance tests with two-type of walls, floor-ceiling systems and all specimens equipped with 2 layers of Type Ⅹ were shown over 1 hour fire resistance performance.

목차

Abstract
1. 서론
2. 경량형강 이용 내화구조 예비 시스템 개발
3. 경량형강 이용 내화구조 표준화 타입 개발
4. 결론
참고문헌