The Purpose of this study was to evaluate reproducibility and linearity according to change of exposure condition of GD in diagnostic X-ray, and compare the dose change and build up characteristic according to delay time in 30 days of glass dosimeter processed preheat and non preheat when measuring accumulation dose of radiation by using glass dosimeter over the long term. The glass dosimeter (AGC Techno Glass Co, Japan) we used, was SC-1 with 30 mm × 40 mm × 9 mm, rectangle shaped and capable of measuring and X-ray. In experiment first which is dose evaluation according to changed tube voltage, sixty GD''s were divided twenty GD''s into three groups (50 kVp, 80 kVp and 100 kVp). Then, each groups of GD were exposured and evaluated. In experiment second which is dose evaluation according to changed tube current, twenty four GD''s were divided twenty GD''s into six groups (5 mAs, 10 mAs, 16mAs, 20 mAs, 25 mAs and 32 mAs). Then, each groups of GD were exposured and evaluated. In experiment third, for obtaining low dose with 0.1 mGy, 1 mGy and 5 mGy, we employed diagnostic generator AccuRay-650R. We compared the build up characteristic over the long haul by exposuring radiation to 30 glass dosimeters sorted into 10 glass dosimeters per tube voltage and current. In non preheat glass dosimeter, initial measured dose was inferior to exposed dose but as time goes on, was close to exposed dose steadily. In 72 hour after experiment end, non preheat glass dosimeters were not indicated the difference from preheat glass dosimeters and statistical analysis were meaningful (p>0.05). Initial measured dose for low glass dosimeter processed preheat was close to exposed dose and stable. After 15days dose was gradually increased. In dose characteristic evaluation of GD for evaluating dose in diagnostic X-ray, the GD is considered as dosimeter which is used not high energy but low energy. However, when reading the dose immediately, Preheat process should be performed in advance. In this study, we make a judgment to measure the dose of glass dosimeter without preheat processing when measuring the accumulation dose of low dose in conclusion.
key Words : reproducibility, linearity, preheat, non-preheat, glass dosimeter,

목차

Ⅰ. 서론 1
Ⅱ. 이론적 배경 5
1. TL 선량계 5
1) TL 현상 5
2) TL 현상의 원리 5
3) TL 선량계의 일반적 성질 7
2. GD (Glass Dosimeter) 9
1) RPL 현상 9
2) RPL 현상의 원리 9
3) GD 와 TLD의 기술적 방법비교 14
4) 선량 판독원리 및 과정 15
3. MOSFET 선량계 19
Ⅲ. 실험기기 및 실험방법 21
1. 실험기기 21
2. 실험방법 24
2.1. 일정한 관전류량 조건에서 관전압 변화에 따른 GD의
선량계 특성 24
1) 선량측정 조건 24
2) 선형성 25
3) 재현성 25
4) 시간에 따른 재현성 25
5) Preheat 선량값과 Non-Preheat 선량값의
시간별 비교 측정 26
2.2. 일정한 관전압 조건에서 관전류량 변화에 따른
GD의 선량 계 특성 26
1) 선량측정 조건 26
2) 선형성 26
3) 재현성 27
4) 시간에 따른 재현성 27
2.3. Preheat과 Non-Preheat의 시간에 따른 Build-Up 28
1) 선량측정조건 28
2) 시간에 따른 build up 특성 측정 30
Ⅳ. 결과 및 고찰 31
1. 일정한 관전류량 조건에서 관전압 변화에 따른
GD의 선량계 특성 실험 결과 31
2. 일정한 관전압 조건에서 관전류량 변화에 따른
GD의 선량계 특성 실험 결과 37
3. Preheat과 Non-Preheat과의 시간에 따른
Build-Up 특성에 관 한 선량계 실험 결과 41
Ⅴ. 결론 45
참고문헌 47
초 록 53
용 어 56

최근 본 자료

전체보기

댓글(0)

0