메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
정재용 (연세대학교) 성정수 (연세대학교) Kim Tae-Hun (Department of Materials Science and Engineering , Yonsei University) Kang Min-Jung (Korea Institute of Science and Technology (KIST)) Jose Joachim (Institute of Pharmaceutical and Medical Chemistry , Westfälischen Wilhelms-Universität Münster) Shin Hyun-Jin (College of Veterinary Medicine , Chungnam National University) Pyun Jae-Chul (연세대학교)
저널정보
한국바이오칩학회 BioChip Journal BioChip Journal Vol.18 No.2
발행연도
2024.6
수록면
318 - 329 (12page)
DOI
10.1007/s13206-024-00151-5

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Fv-antibodies against the nucleocapsid protein (NP) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) were screened from an Fv-antibody library, and a one-step immunoassay was performed to detect SARS-CoV-2 using real viral samples. The Fv-antibody library was prepared using site-directed mutagenesis of the CDR3 region, which was composed of 11 amino acids. To screen the target Escherichia coli from the Fv-antibody library, the expressed probes [N-terminal domain (NTD) labeled with GFP and C-terminal domain (CTD) labeled with GFP] were reacted separately with the Fv-antibody library. After oligonucleotide sequencing, two clones for each probe were selected as the fi nal clones. The screened Fv-antibodies with the binding affi nity to NTD (or CTD) were expressed as soluble proteins, and the affi nity constant (K D) was calculated to be 25.4 nM for NTD and 26.9 nM for CTD. The expressed Fv-antibodies were used for the one-step immunoassay based on switching-peptides, which were bound to the expressed Fv-antibodies. The one-step immu- noassay based on Fv-antibodies could be used for the linear detection of SARS-CoV-2 NP, and the limit of detection (LOD) was estimated to be 9.6 nM (438 ng/mL) for Anti-NTD and 14.1 nM (639 ng/mL) for Anti-CTD. For the demonstration of one-step immunoassay for SARS-CoV-2, NATtrol™ SARS-CoV-2 real sample was used, and the LOD was estimated to be 29.7 copies/mL (Ct = 39.5) using Anti-NTD and 117.8 copies/mL (Ct = 38.0) using Anti-CTD. The measured LOD for the detection of SARS-CoV-2 using a one-step immunoassay based on the switching-peptide was considered feasible for the medical diagnosis of COVID-19. Finally, the interaction between the screened Fv-antibodies and SARS-CoV-2 NP was investigated using docking simulation.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

최근 본 자료

전체보기

댓글(0)

0