논문 기본 정보

자료유형
학술저널
저자정보
이동섭 (서울대학교치과병원) 이정원 (서울대학교치과병원) 안선희 (한국광기술원) 송우섭 (한국광기술원) Ling Li (서울대학교치과병원) 설양조 (서울대학교) 이용무 (서울대학교) 구기태 (서울대학교)
저널정보
대한치주과학회 Journal of Periodontal & Implant Science Journal of Periodontal & Implant Science Vol.54 No.1
발행연도
2024.2
수록면
13 - 24 (12page)
DOI
10.5051/jpis.2203580179

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Purpose: This study investigated the adjunctive effect of light-emitting diodes (LEDs) in the treatment of experimental periodontitis. Methods: Experimental periodontitis was induced by placing ligatures around the mandibular second, third, and fourth premolars of 6 beagles for 3 months. After ligature removal, periodontitis progressed spontaneously for 2 months. The animals’ hemimandibles were allocated among the following 3 groups: 1) no treatment (control), 2) scaling and root planing (SRP), and 3) SRP with LED irradiation at 470-nm and 630-nm wavelengths (SRP/LED). The probing pocket depth (PPD) and gingival recession (GR) were measured at baseline, 6 weeks, and 12 weeks. The clinical attachment level (CAL) was calculated. After 12 weeks, histological and histomorphometric assessments were performed. The distances from the gingival margin to the apical extent of the junctional epithelium (E) and to the connective tissue (CT) attachment were measured, as was the total length of soft tissue (ST). Results: PPD and CAL increased at 12 weeks compared with baseline in the control group (6.31±0.43 mm to 6.93±0.50 mm, and 6.46±0.60 mm to 7.61±0.78 mm, respectively). PPD and CAL decreased at 12 weeks compared with baseline in the SRP group (6.01±0.59 to 4.81±0.65 mm, and 6.51±0.98 to 5.39±0.93 mm, respectively). PPD and CAL decreased at 12 weeks compared with baseline in the SRP/LED group (6.03±0.39 to 4.46±0.47 mm, and 6.11±0.47 to 4.78±0.57 mm, respectively). The E/ST and CT/ST ratios significantly differed among the 3 groups (P<0.05). The clinical parameters and histologic findings demonstrated that 470-nm and 630-nm wavelength LED irradiation accompanying SRP could improve treatment results. Conclusions: Within the study limitations, 470 nm and 630 nm wavelength LED irradiation might provide additional benefits for periodontitis treatment.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

최근 본 자료

전체보기

댓글(0)

0