메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Hee-Jung Yeom (Korea Research Institute of Standards and Science) Gwang-Seok Chae (Korea Research Institute of Standards and Science) Jung-Hyung Kim (Korea Research Institute of Standards and Science) Hyo-Chang Lee (Korea Aerospace University)
저널정보
한국진공학회(ASCT) Applied Science and Convergence Technology Applied Science and Convergence Technology Vol.33 No.2
발행연도
2024.3
수록면
41 - 44 (4page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
As nanoelectronic devices continue to shrink in response to demands for smaller and faster low-power, high-density devices, wasteful fabrication techniques are being replaced with methods that predetermine processing windows based on plasma parameter measurements. A cutoff probe comprising coaxial cables wrapped in Teflon is typically used for this measurement. However, because Teflon can be destroyed under high-density plasma conditions, a change in the dielectric material of the coaxial cable may be considered for process plasma or high-density plasma measurements. However, the nature of these changes has not been examined. Hence, this study analyzes the plasma measurement characteristics of a cutoff probe using electromagnetic wave simulations and a plasma equivalent circuit model focusing on the dielectric permittivity and thickness of the coaxial cable-based cutoff probe. According to the results, as the dielectric constant of the insulator of the coaxial cable increased from 1 to 20, the transmission intensity at the cutoff frequency decreased from –68 to –81 dB. Furthermore, with the increased thickness of the insulator, the transmission intensity at the cutoff frequency increased from –80 to –64 dB. The characteristic changes are explained using a circuit model that verifies that changes to the insulator’s dielectric constant and thickness affect the characteristic impedance of the cable, but not the plasma density measured by the cutoff probe. Nevertheless, the intensity of the observed transmission spectrum is affected. Hence, these findings are expected to contribute to the optimization of cutoff probes used for high-density plasma parameter measurements.

목차

ABSTRACT
1. Introduction
2. Simulation details
3. Results and discussion
References

참고문헌 (0)

참고문헌 신청

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-151-24-02-089575604