메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
손수희 (식품위생안전연구소) 이상일 (에코해빗) 박민혜 (식품위생안전연구소) 김현숙 (식품위생안전연구소)
저널정보
한국조리학회 Culinary Science & Hospitality Research Culinary Science & Hospitality Research Vol.30 No.1(Wn.162)
발행연도
2024.1
수록면
74 - 85 (12page)
DOI
10.20878/cshr.2024.30.1.009

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
This study was conducted to determine the safety of food contact surfaces of reusable cups used in commercial cleaning facilities. To determine the effectiveness of cleaning reusable cups, we analyzed the microbiological risks associated with each step of the reusable cup cleaning process, workplace environment, cleaning water, equipment and tools, and workers, and analyzed residual allergens and microplastics. As a result of microbial analysis by cleaning process, the aerobic plate count and coliform group upon receipt were 0∼3.20±0.20 log CFU/100 ㎠, but after the disinfection and drying process, the aerobic plate count and coliform group were not detected. No pathogenic microorganisms were detected in any process. In the workplace environment, an aerobic plate count of 1.00±0.00 CFU/plate was detected in the disinfection and drying room in the air-borne bacteria test, but in the remaining tests, neither aerobic plate count nor coliforms were detected. In equipment and tools, the aerobic plate count of the brush was detected at 2.36±0.04∼3.04±0.24 log CFU/100 cm2, coliforms were detected at 0∼2.04±0.06 log CFU/100 ㎠, and Staphylococcus aureus was not detected. After disinfection, no aerobic plate counts, coliforms, or Staphylococcus aureus were detected on the inspection belt. Residual allergens tested for each cleaning process were detected during the warehousing and soaking processes, but not during the foam rinsing process. As for microplastics, 3 polyethylene (PE) and 2 polypropylene (PP) were confirmed in general reusable cups, and 3 PE and 3 PP were confirmed in reusable cups with QR code stamps, so there was no significant difference. The results of this study suggest that commercial cleaning facilities ensure the safety of food contact surfaces of reusable cups, and as the number of commercial cleaning facilities increases, it can be used as useful data to establish safe cleaning facilities.

목차

ABSTRACT
1. 서론
2. 연구 내용 및 방법
3. 결과 및 고찰
4. 요약 및 결론
REFERENCES

참고문헌 (35)

참고문헌 신청

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-151-24-02-089272064