메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Sang Hyuk Park (University of Ulsan College of Medicine) Heejeong Kim (Pusan National University School of Medicine) Hyerin Kim (Pusan National University School of Medicine) Hyerim Kim (Pusan National University School of Medicine)
저널정보
대한임상검사정도관리협회 Journal of Laboratory Medicine And Quality Assurance Laboratory Medicine and Quality Assurance 제45권 제2호
발행연도
2023.6
수록면
58 - 64 (7page)
DOI
10.15263/jlmqa.2023.45.2.58

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: The aim of our study is to examine the performance of an algorithm used by autoverification middleware (LimasVfy; Hwasan System, Korea) in the diagnostic hematology laboratory of a single tertiary hospital in Korea. Methods: In this study, we included manually verified complete blood count (CBC) results from June 2019 to January 2020, as well as CBC results from February 2020 to September 2021 that underwent both autoverification and manual verification. The autoverification rates and turnaround time (TAT) of both datasets were compared, thereby obtaining an effective comparison between the period before and after the introduction of the autoverification system. Results: After introducing autoverification, the rates of autoverification and manual verification were 64.6% and 35.4%, respectively. Of the manually verified cases, those with delta check, panic value, flags, and critical values were 46.4%, 28.2%, 19.8%, and 5.6%, respectively. After the autoverification rule related to platelet count was modified in August 2020, the rate slightly increased from 63.9% to 64.8%, and critical value reporting rates decreased from 26.8% to 2.4%. Prior to autoverification, the median time from reception to production of results/from production of results to final reports was 9.6/35.1 minutes. After introducing autoverification, it was 10.0/39.9 minutes in manually verified cases and 3.2/0.0 minutes in autoverified cases. Total time, that is the product of total number of cases and average TAT, decreased from 350,000 to 200,000 minutes. Rate of excess TAT also decreased from 0.065% to 0.045%. Conclusions: LimasVfy would be a useful tool in reducing TAT and verification workload in the CBC testing, and this study can provide useful information in determining the introduction of autoverification systems in the setting of diagnostic hematology.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0