메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Kim Hyun-Jin (School of Nursing Hanyang University Seoul Korea.) Kim Sunhae (Department of Psychiatry College of Medicine Hanyang University Seoul Korea.) Son Youkyoung (Department of Nursing Hanyang University Medical Center Seoul Korea.) Youn Insook (Department of Nursing Hanyang University Medical Center Seoul Korea.) Lee Kounseok (Department of Psychiatry College of Medicine Hanyang University Seoul Korea.)
저널정보
대한의학회 Journal of Korean Medical Science Journal of Korean Medical Science Vol.38 No.6
발행연도
2023.2
수록면
1 - 11 (11page)
DOI
10.3346/jkms.2023.38.e41

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: The Ask Suicide-Screening Questions (ASQ) tool is a simple suicide screening tool developed to screen patient suicide risk (SR). The purpose of this study was to verify the reliability and validity of the ASQ tool in hospitalized patients. Methods: The internal consistency and test-retest reliability of the South Korean version of the ASQ tool were verified in 99 hospitalized patients admitted to a tertiary medical institution in Seoul. To verify the correlations and validity of each convergence with other scales, the Mini-International Neuropsychiatric Interview (MINI), Patient Health Questionnaire-9 (PHQ-9), Generalized Anxiety Disorder-7 (GAD-7), and Satisfaction with Life Scale (SWLS) were also conducted to determine convergent and discriminant validity. Then, the receiver operating characteristic (ROC) curve diagnosis values for suicide and depression levels with the highest correlations were analyzed. Results: As a result, Cronbach’s alpha was 0.826, and when each item was removed sequentially, Cronbach’s alpha ranged from 0.736–0.840, showing stable internal consistency. Most of the corrected item-total correlation were over 0.500; however, a relatively low correlation was shown for the fourth and fifth questions, which had values of 0.429 and 0.410, respectively. The test-retest reliability was 0.830, and the MINI and PHQ-9 showed high values of 0.872 and 0.672, respectively. The area under the curve (AUC) according to the ASQ diagnosis value was also the highest for the MINI (0.936). Conclusion: The validity and reliability of the South Korean version of the ASQ tool were demonstrated. Through this validation, the ASQ tool can be used for simple suicide risk screening (SRS) in hospitalized patients.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0