메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Biju Viswambharan (Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER) Puducherry India) Manjini Jeyaram Kumari (Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER) Puducherry India) Gopala Krishnan (Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER) Puducherry India) Lakshmi Ramamoorthy (Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER) Puducherry India)
저널정보
대한중환자의학회 Acute and Critical Care Acute and Critical Care 제36권 제4호
발행연도
2021.11
수록면
374 - 379 (6page)
DOI
10.4266/acc.2021.00024

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background Mechanical ventilation is a lifesaving intervention for critically ill patients but can produce the major complication of ventilator-associated pneumonia (VAP). Inappropriately inflated endotracheal tubes cause potential harm due to high or low pressure; this can be prevented through monitoring protocols. Methods A cross-sectional study of 348 cuff pressure readings was performed with intubated and mechanically ventilated patients to evaluate the exact proportion of patients in intensive care units (ICUs) where the cuff pressure is optimal and to identify the ICUs where device-based monitoring is available to produce a lower proportion of sub-optimal cuff pressure cases. Every three days, cuff pressure was assessed with a handheld cuff pressure manometer. The corresponding VAP rates of those ICUs were obtained from the hospital infection control department. Results Cuff pressure of 40.2% was the lower cutoff for the high category, that of optimal was 35.3%, and the highest cutoff of sub-optimal was 24.4%. This study also showed ICUs that had cuff pressure monitoring devices and protocols. Active measurement protocols had a higher proportion of optimal cuff pressure (58.5%) and a lower proportion of sub-optimal and high cuff pressure (19.5% and 22.0%) compared to ICUs with no device-based monitoring protocols. Furthermore, the VAP rate of ICUs exhibited a weak positive correlation with sub-optimal cuff pressure. Conclusions Device-based cuff pressure monitoring is essential in maintaining adequate cuff pressure but often is inadequate, resulting in high readings. Therefore, this study suggests that device-based cuff pressure monitoring be practiced.

목차

등록된 정보가 없습니다.

참고문헌 (19)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0