메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Alberto Borges Peixoto (University of Uberaba) Taciana Mara Rodrigues da Cunha Caldas (University of Uberaba) Luisa Almeida Tahan (University of Uberaba) Caetano Galvão Petrini (University of Uberaba) Wellington P. Martins (University of São Paulo) Fabricio Da Silva Costa (Federal University of São Paulo) Edward Araujo Júnior (Federal University of São Paulo (EPM-UNIFESP))
저널정보
대한산부인과학회 Obstetrics & Gynecology Science Obstetrics & Gynecology Science 제60권 제4호
발행연도
2017.7
수록면
329 - 335 (7page)
DOI
https://doi.org/10.5468/ogs.2017.60.4.329

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Objective: To assess the predictive capacity of cervical length (CL) measurement underwent during the second trimester ultrasound for prediction preterm birth <32, 34, and 37 weeks of gestation in an unselected risk population. Methods: A retrospective cohort study was performed with 751 singleton pregnancies between 20 and 24+6 weeks of gestation. The CL measurement (mm) using the transvaginal route was obtained in a sagittal view and the calipers positioned to measure the linear distance between the triangular area of echodensity at the external os and the internal os. To compare the preterm (<37 weeks) and term births (≥37 weeks), we used unpaired t test. We assessed whether the CL measurement was dependent of gestational age by performing a linear regression and assessing the coefficient of determination (R²). We additionally assessed the accuracy of CL measurement to predict preterm birth by assessing the area under receiver operating characteristics curves with its respective confidence intervals (CIs) 95%. Results: Preterm birth <37 weeks was found in 13.6% (102/751) of pregnant women. Short cervix (≤25 mm) was found in 2.7% (20/751) of pregnancies. Only 30% (6/20) of pregnant women with short cervix have used progesterone to prevent preterm birth. There was a weak correlation between CL measurement and gestational age at delivery (R2=0.01, P=0.002). Receiver operating characteristics curve analysis of the ability of CL measurement to predict preterm birth <32, 34, and 37 weeks, showed an area under the curve of 0.693 (95% CI, 0.512 to 0.874), 0.472 (95% CI, 0.353 to 0.591), 0.490 (95% CI, 0.426 to 0.555), respectively. Conclusion: There was a weak correlation between CL measurement and gestational age at delivery. In an unselected population, CL measurement screening at 20 to 24+6 weeks of gestation does not seem to be a good predictor of preterm birth.

목차

등록된 정보가 없습니다.

참고문헌 (18)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0