Jung-Hyuk Lee (Department of Periodontology School of Dentistry Chonnam National University Gwangju Republic of Ko) Seong-Jun Ham (Department of Dental Science Graduate School School of Dentistry Chonnam National University Gwangj) Jin-Wook Shin (Kuwotech Co. Ltd. Gwangju Republic of Korea) Cheol-Woong Jeong (Kuwotech Co. Ltd. Gwangju Republic of Korea) Jeong-In Choi (Department of Periodontology School of Dentistry Chonnam National University Gwangju Republic of Ko) Young-Joon Kim (Department of Periodontology School of Dentistry Chonnam National University Gwangju Republic of Ko)
저널정보
조선대학교 치의학연구원 Oral Biology Research Oral Biology Research 제46권 제2호
발행연도
2022.6
수록면
61 - 70 (10page)
DOI
10.21851/obr.46.02.202206.61

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
The current study introduces photocurable macromolecular resin (KIS resin) and aims to assess its use as a basic material for implant surgical stent fabrication using 3D printing and the digital light processing (DLP) technique. The biological and physical properties of KIS resin were evaluated, and radiological analysis was performed to assess the clinical accuracy of a 3D-printed surgical stent. The physical characteristics were analyzed in accordance with the guidelines of certified standards, and cell adhesion analysis was performed to evaluate the viability of human gingival fibroblast (hGF) cells exposed to KIS resin and conventional orthodontic acrylic resin. Radiological analysis of animals was carried out by pairwise overlap of pre- and postoperative images. The physical characteristics of KIS resin met the ISO 20795-1, ASTM D695, and ASTM D638 standards. The hGF cells on KIS resin samples exhibited better cell attachment and connection compared to those exposed to conventional resins. The findings of the radiological analyses showed statistically significant differences in the deviations between DLP-printed surgical stents and conventional stents, with the horizontal linear deviations being smaller in the coronal and middle levels of the former. Moreover, the angular deviation was also smaller in the DLP stent group. Therefore, KIS resin exhibited favorable physical properties and cell viability, highlighting its potential for use as a basic material for 3D-printed implant surgical guides. Further evaluation of the use of implant surgical stents fabricated using KIS resin and the DLP method as a proper tool for implant placement with clinical utility should be carried out.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0