메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
이재승 (세계아이티(주) 기업부설연구소) 양성환 (한국복지대학교) 권대철 (신한대학교)
저널정보
한국방사선산업학회 방사선산업학회지 방사선산업학회지 제12권 제3호
발행연도
2018.1
수록면
223 - 231 (9page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
The purpose of this study is to evaluate the effective dose of radon by radon exposureby measuring the concentration of radon in university lecture room. The measurement of radonconcentration was made in two lecture rooms on the first floor of reinforced concrete structurefrom March to May, 2018. On weekends when there was no use of the lecture room, it wasmeasured for 24 hours in a closed state for 12 hours before measurement, and continued for 12hours in 12 hours and 12 hours in continuous for 5 weeks. The indoor radon concentration wasmeasured by a radon meter and an analysis program, and the indoor radon concentration per unittime was converted in real time. The annual effective dose and the continuously measured radonconcentration due to radon inhalation were analyzed for mean and standard deviation, coefficientof variation, indoor radon concentration range, and quartile range. The closed lecture room radonconcentration was estimated to be 67~81.8 Bq·m-3 (mean 74.5±6.65 Bq·m-3) and the effectivedose per year was 0.289~0.353 mSv·y-1. The average radon concentration in normal operationwas 26.6~54 Bq·m-3 (mean 40.2±8.34 Bq·m-3), which was 54% lower than the closed room. Themean radon concentration was 48.3±5.94 Bq·m-3 before the start of the academic year, 31.3±6.64Bq·m-3, the average radon concentration was 41.9±9.64 Bq·m-3, 0.115~0.233 mSv·y-1. Radonconcentration 32.2~54 Bq·m-3 (average 45.7±5.2 Bq·m-3) at 18:00 o’clock without the lecture at09:00 the following day, quaternary range 43.9~48.8 Bq·m-3, annual effective dose 0.190~0.211mSv·y-1 respectively. Radon concentration was 26.6~40 Bq·m-3 (average 31.3±6.64 Bq·m-3) from09:00 am to 18:00 pm, which was reduced by 68.5% compared to the classroom without class, andthe quartile range was 28.3~33.8 Bq·m-3, and annual effective dose was 0.122~0.146 mSv·y-1. The average radon concentration in the lecture room was 10 min resting time (31.8±6.54 Bq·m-3)after lecture 50 minutes, 10 minutes resting time (32.3±7.18 Bq·m-3) after 1 hour and 50 minuteslecture, and 0.008~0.013 mSv·y-1. The average indoor radon concentration of 40.2±8.92 Bq·m-3 for 2 hours and 50 minutes of continuous use in classroom, the annual effective dose of 0.01~0.016mSv·y-1 for 50 minutes or 1 hour 50 minutes, indoor radon concentration and annual effectivedose of about 30% respectively. The radon concentrations in the lecture room were measured atlower levels than the indoor radon concentration control standards, and the hazard coefficientsfrom the radon inhalation in these environments were evaluated to be lower than the populationmean life time cancer risk.

목차

등록된 정보가 없습니다.

참고문헌 (30)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0