메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Won-Kyu Choi (Department of Laboratory Medicine Asan Medical Center University of Ulsan College of Medicine Seoul) Hyun-Ki Kim (Department of Laboratory Medicine Asan Medical Center University of Ulsan College of Medicine Seoul) Woochang Lee (Department of Laboratory Medicine Asan Medical Center University of Ulsan College of Medicine Seoul) Sail Chun (Department of Laboratory Medicine Asan Medical Center University of Ulsan College of Medicine Seoul) Won-Ki Min (Department of Laboratory Medicine Asan Medical Center University of Ulsan College of Medicine Seoul)
저널정보
대한임상검사정도관리협회 Journal of Laboratory Medicine And Quality Assurance Journal of Laboratory Medicine And Quality Assurance Vol.41 No.4
발행연도
2019.1
수록면
207 - 213 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: Prostate-specific antigen (PSA) is widely used as a tumor marker of prostate cancer, but it is not specific for cancer. Numerous efforts have been made to find another tumor marker that can replace PSA. Recently, the Prostate Health Index (PHI) has been introduced, which shows higher diagnostic performance for prostate cancer than PSA. In this study, we evaluated the performance of the UniCel DxI 800 (Beckman Coulter, USA) for quantitative measurement of total PSA (tPSA), free PSA (fPSA), and [-2]proPSA used for calculating the PHI. Methods: The precision, linearity, and limit of detection of the three items, as well as the correlation between the UniCel DxI 800 (Beckman, USA) and a comparable instrument in the Asan Medical Center, the Alinity i (Abbott, USA), were evaluated in accordance with the Clinical Laboratory Standards Institute guidelines. Results: The total coefficient of variation for the three items was less than 5%. Linearity was observed for each manufacturer-claimed analytical measurement range, with R2=0.99. The claimed limit of blank and limit of detection were verified. The results of the UniCel DxI 800 showed good correlation with those of the Alinity i (tPSA, r =0.995; fPSA, r =0.994). Conclusions: The UniCel DxI 800 showed good analytical performance. Therefore, it will be useful to use the UniCel DxI 800 in the clinical laboratory to measure the diagnostic markers of prostate cancer.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0