메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
공부주 (국립환경과학원) 김종현 (국립환경과학원) 임경미 (충청북도 보건환경연구원) 우은지 (국립환경과학원) 조강남 (국립환경과학원 대기환경과) 박정민 (국립환경과학원) 김영우 (국립환경과학원)
저널정보
한국냄새환경학회 실내환경 및 냄새 학회지 실내환경 및 냄새 학회지 제18권 제4호
발행연도
2019.1
수록면
330 - 339 (10page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
In this study, the grid field olfactory odor method was supplemented to the domestic situation in the surrounding areas of a domestic science industrial complex. The actual condition of the occurrence of odor frequency in the field was then investigated over the first period of late spring to summer and the second period of autumn in 2017. The frequency of odor occurrence in the area around the science industrial complex was increased as odor discharge facilities in the nearby area were concentrated. The odor occurrence frequency of the total period was 0.09~0.28, that of the first period was 0.08~0.32, and that of the second period was 0.05~0.25. The odor occurrence frequency in summer was higher than in autumn. The frequency by which the measurement of odor occurrence by smell type was most dominant was mainly smell of chemicals, plastics, and livestock houses during the first period, and the smell of chemicals, burning gases, and plastics during the second period. And the frequency of each smell type was judged to be different according to season. The odor occurrence frequency was measured as higher than 0.15, which is the standard of Germany's odor frequency in an industrial area, and it was judged that measures for odor management in the region were necessary. Since most of the odor discharge facilities are non-continuous systems and the odor generation frequency is more important than the concentration of the minimum detection concentration, it was judged that the German grid method can reflect the odor occurrence characteristics of the odor complaints or receptors for a certain period of time compared to the domestic measurement method. In the future, it was judged that the field olfactory odor method would be able to replace the evaluation method of odor assessment in Korea with the survey method of odor assessment under actual conditions in areas where it is difficult to access the odor discharge source or the receptor where odor complaints occur.

목차

등록된 정보가 없습니다.

참고문헌 (7)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0