메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Ginga Suzuki (Department of Removable Prosthodontics Tsurumi University School of Dental Medicine Kanagawa Japa) Satoshi Shimizu (Department of Removable Prosthodontics Tsurumi University School of Dental Medicine Kanagawa Japa) Mana Torii (Department of Removable Prosthodontics Tsurumi University School of Dental Medicine Kanagawa Japa) Ai Tokue (Department of Removable Prosthodontics Tsurumi University School of Dental Medicine Kanagawa Japa) Guo Ying (Department of Prosthodontics Stomatological School of Capital Medical University Beijing China) Masao Yoshinari (Department of Dental Engineering Tsurumi University School of Dental Medicine Kanagawa Japan) Noriyuki Hoshi (Prosthodontics & Oral Implantology Graduate School Kanagawa Dental University Kanagawa Japan) Katsuhiko Kimoto (Prosthodontics & Oral Implantology Graduate School Kanagawa Dental University Kanagawa Japan) Hiromi Miura (Department of Mechanical Engineering Toyohashi University of Technology Aichi Japan) Tohru Hayakawa (Department of Dental Engineering Tsurumi University School of Dental Medicine Kanagawa Japan) Chikahiro Ohkubo (Department of Removable Prosthodontics Tsurumi University School of Dental Medicine Kanagawa Japa)
저널정보
대한치과보철학회 The Journal of Advanced of Prosthodontics The Journal of Advanced of Prosthodontics 제12권 제6호
발행연도
2020.1
수록면
369 - 375 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
PURPOSE. This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure. MATERIALS AND METHODS. The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test. RESULTS. Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/rpm in machinability tests (P<.05). CONCLUSION. Although the wear resistance and plaque adherence of MDFTi were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.

목차

등록된 정보가 없습니다.

참고문헌 (35)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0