Chung, Dae-Yeong (Department of Neurosurgery, School of Medicine, Kyungpook National University) Cho, Dae-Chul (Department of Neurosurgery, School of Medicine, Kyungpook National University) Lee, Sun-Ho (Department of Neurosurgery, School of Medicine, Kyungpook National University) Sung, Joo-Kyung (Department of Neurosurgery, School of Medicine, Kyungpook National University)
저널정보
대한신경외과학회 대한신경외과학회지 대한신경외과학회지 제41권 제2호
발행연도
2007.1
수록면
111 - 117 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Objective : The objective of this study was to validate the effects of a titanium mesh cage and dynamic plating in anterior cervical stabilization after corpectomy. Methods : A retrospective study was performed on 31 consecutive patients, who underwent anterior cervical reconstruction with a titanium mesh cage and dynamic plating, from March 2004 to February 2006. Twenty-four patients had 1-level and 7 had 2-level corpectomies. Ten patients underwent surgery with a cage of 10-mm diameter and 21 with 13-mm diameter. Neurological status and outcomes were assessed according to Odom's criteria. Sagittal angle, coronal angle, settling ratio, sagittal displacement, and cervical lordosis were used to evaluate the radiological outcomes. Results : In overall, 26 [83.9%] of 31 showed excellent or good outcomes. Thirteen percent [4 cases] of the patients developed surgical complications, such as hoarseness, transient dysphagia, or nerve root palsy. Seven [22.6%] patients had reconstruction failure:5 [20.8%] in the 1-level corpectomy group and 2 [28.5%] in the 2-level corpectomy group. Revisions were required in 2 patients with plate pullout due to significant instability. However, none of 5 patients who demonstrated cage displacement or screw pullout, underwent a revision. Radiographs revealed bony consolidation in 96.3% of the patients, including 6 patients with implantation failure during the follow-up period. Conclusion : Based on our preliminary results, the titanium mesh cage and dynamic plating was effective for cervical reconstruction after corpectomy. The anterior cervical reconstruction performed with dynamic plates is considered to reduce stress shielding and greater graft compression that is afforded by the unique plate design.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0