메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Ko, Jin-Hyouk (Food Safety Center, Research and Development Institute, Namyang Dariy Co. Ltd.) Kwak, Byung-Man (Food Safety Center, Research and Development Institute, Namyang Dariy Co. Ltd.) Ahn, Jang-Hyuk (Food Safety Center, Research and Development Institute, Namyang Dariy Co. Ltd.) Shim, Sung-Lye (Department of Food and Nutrition, Chosun University) Kim, Kyong-Su (Department of Food and Nutrition, Chosun University) Yoon, Tae-Hyung (Nutrition and Functional Food Research Team, Korea Food and Drug Administration) Leem, Dong-Gil (Nutrition and Functional Food Research Team, Korea Food and Drug Administration) Jeong, Ja-Young (Nutrition and Functional Food Research Team, Korea Food and Drug Administration)
저널정보
한국축산식품학회 한국축산식품학회지 한국축산식품학회지 제32권 제5호
발행연도
2012.1
수록면
571 - 577 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
This study was carried out to develop an analytical method for the determination of vitamin D in infant formula. Vitamin D was determined by column-switching high-performance liquid chromatography (HPLC) equipped with a reversed phase column and UV detector after saponification and extraction of the formula with an organic solvent. A preseparation column ($C_8$), focusing column ($C_{18}$), analytical column ($C_{18}$) and UV-Vis detector (254 nm) were used. The limits of detection (LOD) and the limits of quantification (LOQ) for vitamin D were estimated to be $1.51{\mu}g/kg$ and $4.95{\mu}g/kg$, respectively. The linearity, recovery, precision and accuracy of the analytical method for vitamin D were evaluated through the application of a SRM (Standard Reference Material) 1846 (National Institute of Standard & Technology, USA). The linearity of this method was calculated with a value of the coefficient of determination ($r^2$) ${\geq}0.9999$. The recovery of vitamin D was $85.20{\pm}3.00%$. The intra-assay precision for vitamin D was between $1.68{\pm}0.03%$ and $5.75{\pm}0.33%$, and the inter-assay precision for vitamin D ranged from $1.73{\pm}0.03%$ to $2.96{\pm}0.09%$. The intra-assay accuracy for vitamin D was between $100.03{\pm}2.77%$ and $102.01{\pm}0.59%$, and the inter-assay accuracy for vitamin D ranged from $99.00{\pm}1.53%$ to $102.01{\pm}3.04%$. The proposed method is optimal for the separation and quantification of vitamin D from infant formula.

목차

등록된 정보가 없습니다.

참고문헌 (19)

참고문헌 신청

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0