Kim, Heesun (KEPCO Research institute, Korea Electric Power Corporation) Han, Young Hee (KEPCO Research institute, Korea Electric Power Corporation) Yang, Seong-Eun (KEPCO Research institute, Korea Electric Power Corporation) Yu, Seung-Duck (KEPCO Research institute, Korea Electric Power Corporation) Park, Byung Jun (KEPCO Research institute, Korea Electric Power Corporation) Park, Kijun (KEPCO Research institute, Korea Electric Power Corporation) Yoo, Jaeun (KEPCO Research institute, Korea Electric Power Corporation) Kim, Hye-Rim (KEPCO Research institute, Korea Electric Power Corporation) In, Sehwan (Korea Institute of Machinery and Materials [KIMM]) Hong, Yong Joo (Korea Institute of Machinery and Materials [KIMM]) Yeom, Hankil (Korea Institute of Machinery and Materials [KIMM])
저널정보
한국전력공사 KEPCO Journal on electric power and energy KEPCO Journal on electric power and energy 제1권 제1호
발행연도
2015.1
수록면
141 - 144 (4page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0