메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Mubarak, Sarah (Reproductive Medicine Unit, Department of Obstetrics and Gynaecology, General Hospital Kuala Lumpur) Yusoff, Noor Haliza (Reproductive Medicine Unit, Department of Obstetrics and Gynaecology, General Hospital Kuala Lumpur) Adnan, Tassha Hilda (National Clinical Research Centre, General Hospital Kuala Lumpur)
저널정보
대한생식의학회 Clinical and experimental reproductive medicine : CERM Clinical and experimental reproductive medicine : CERM 제46권 제2호
발행연도
2019.1
수록면
87 - 94 (8page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Objective: The primary objective of this study was to compare clinical pregnancy rates in intrauterine insemination (IUI) treatment cycles with transabdominal ultrasound guidance during intrauterine catheter insemination (US-IUI) versus the "blind method" IUI without ultrasound guidance (BM-IUI). The secondary objective was to compare whether US-IUI had better patient tolerability and whether US-IUI made the insemination procedure easier for the clinician to perform compared to BM-IUI. Methods: This was a randomized controlled trial done at the Reproductive Medicine Unit of General Hospital Kuala Lumpur, Malaysia. We included women aged between 25 and 40 years who underwent an IUI treatment cycle with follicle-stimulating hormone injections for controlled ovarian stimulation. Results: A total of 130 patients were recruited for our study. The US-IUI group had 70 patients and the BM-IUI group had 60 patients. The clinical pregnancy rate was 10% in both groups (p> 0.995) and there were no significant difference between the groups for patient tolerability assessed by scores on a pain visual analog scale (p= 0.175) or level of difficulty for the clinician (p> 0.995). The multivariate analysis further showed no significant increase in the clinical pregnancy rate (adjusted odds ratio, 1.07; 95% confidence interval, 0.85-1.34; p= 0.558) in the US-IUI group compared to the BM-IUI group even after adjusting for potential covariates. Conclusion: The conventional blind method for intrauterine catheter insemination is recommended for patients undergoing IUI treatment. The use of ultrasound during the insemination procedure increased the need for trained personnel to perform ultrasonography and increased the cost, but added no extra benefits for patients or clinicians.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0