메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Lee, Nakwon (Department of Internal Medicine, Yonsei University Wonju College of Medicine) Kim, Sang-Ha (Department of Internal Medicine, Yonsei University Wonju College of Medicine) Kwon, Woocheol (Department of Radiology, Yonsei University Wonju College of Medicine) Lee, Myoung Kyu (Department of Internal Medicine, Yonsei University Wonju College of Medicine) Yong, Suk Joong (Department of Internal Medicine, Yonsei University Wonju College of Medicine) Shin, Kye Chul (Department of Internal Medicine, Yonsei University Wonju College of Medicine) Jung, Ye-Ryung (Department of Internal Medicine, Yonsei University Wonju College of Medicine) Choi, Yeun Seoung (Department of Internal Medicine, Yonsei University Wonju College of Medicine) Choi, Jiwon (Department of Internal Medicine, Yonsei University Wonju College of Medicine) Choi, Ji Sun (Department of Internal Medicine, Yonsei University Wonju College of Medicine) Lee, Won Yeon (Department of Internal Medicine, Yonsei University Wonju College of Medicine)
저널정보
대한결핵 및 호흡기학회 Tuberculosis and Respiratory Diseases 결핵 및 호흡기 질환 제77권 제6호
발행연도
2014.1
수록면
251 - 257 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: Transbronchial lung biopsy (TBLB) is a valuable diagnostic tool for peripheral pulmonary lesions. The diagnostic yield of TBLB reportedly ranges from 41%-60%. Many studies demonstrated the various factors that influence the yield of TBLB, including size, location, and distance from the carina or pleura. However, no study has evaluated the effects of the bronchoscope diameter. We evaluated whether the bronchoscope diameter affected the diagnostic yield of TBLB. Methods: We reviewed records from 178 patients who underwent TBLB using bronchoscopes of two different diameters (5.7 mm, thick outer diameter, Olympus BF-200; 4.9 mm, thin, BF-260). The fluoroscopic guidance rates, yield of TBLB and flexible bronchoscopy (FB) were compared between the two groups. Additionally, we compared the results of the procedures with respect to diagnosis, distance from the pleura, and size of the lesion. Results: The results of fluoroscopic guidance, TBLB, and FB yield using thin diameter bronchoscope were significantly better than those obtained with a thick diameter bronchoscope (p=0.021, p=0.036, and p=0.010, respectively). Particularly, when the distance from the pleura was ${\leq}10mm$, success rates for fluoroscopic guidance and FB with thin bronchoscope were higher (p=0.013 and p=0.033, respectively), as compared to with thick bronchoscope. Conclusion: A thinner diameter bronchoscope increased the yield of bronchoscopy, and bronchial washing in conjunction with TBLB was useful in the diagnosis of peripheral pulmonary nodules.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0