메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
김외정 (서울아산병원 핵의학과) 천준홍 (서울아산병원 핵의학과) 유선희 (서울아산병원 핵의학과) 조시만 (서울아산병원 핵의학과)
저널정보
대한핵의학기술학회 핵의학기술 핵의학기술 제13권 제3호
발행연도
2009.1
수록면
143 - 146 (4page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Purpose: We use the centrifugation of refrigeration state in separation of blood serum, Anti-ds-DNA, Vitamin $B_{12}$/Folate and GAD-Ab assay. However, Cortisol urine and 25-Hydroxyvitamin $D_3$ ($25OHD_3$) are conducted centrifuge at room temperature. This is troublesome that change centrifugation temperature into room temperature due to using of most assays at cold temperature. Therefore when using centrifuge after extraction of Cortisol urine and $25OHD_3$, we conducted researches on effect of the centrifugation temperature in assay results. Materials and Methods: In Cortisol urine, add dichloromethane 1.0 mL in urine $500\;{\mu}L$, mix for 15 minutes, and then centrifuge for 8 minutes at 2600rpm. In $25OHD_3$ add acetonitrile 0.5 mL in serum $200\;{\mu}L$, and then centrifuge for 8 minutes at 2600rpm. Those experiments were conducted centrifuge at room temperature and $4^{\circ}C$. And experiments conducted immediately after centrifugation at $4^{\circ}C$ and standing for 20 minutes after centrifugation $4^{\circ}C$. Results: In Cortisol urine, room temperature result in 1.93, 2.18, 2.43, 9.45, 14.2 (${\mu}g/dL$). Experiments of performing immediately after centrifuge at $4^{\circ}C$ result in 1.8, 2.0, 2.3, 8.1, 13.7 (${\mu}g/dL$). Experiments of performing after 20 minutes result in 2.1, 2.1, 2.7, 9.95, 14.35 (${\mu}g/dL$). On the other hand, the $25OHD_3$ tests conducted at room temperature result in 7.13, 26.6, 35.8, 48.2, 74.8 (ng/dL). Experiments were conducted immediately by pipetting after $4^{\circ}C$ centrifugation result in 7.53, 30.9, 40.3, 61.5, 89.1 (ng/dL) as results are higher than experiments at room temperature. The experiments that conducted centrifuge at $4^{\circ}C$ and then left at room temperature for 20 minutes result in 7.40, 32.4, 41.3, 51.6, 85.6 (ng/dL). Conclusions: Experiments were conducted by using centrifuge at $4^{\circ}C$ are higher or lower than room temperature. The differences between results of standing for 20 minutes after centrifuge at $4^{\circ}C$ and those of centrifuge at room temperature are less than conducting immediately. It is concerned that experiments conducted immediately after centrifuge at $4^{\circ}C$ are incorrect, because tubes become dim due to temperature differences between $4^{\circ}C$ and room temperature. Therefore, it is desirable to centrifuge at room temperature as manual and we should pipet promptly without stopping.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0