메뉴 건너뛰기
Library Notice
Institutional Access
If you certify, you can access the articles for free.
Check out your institutions.
ex)Hankuk University, Nuri Motors
Log in Register Help KOR
Subject

The Effect of Abutment Inclined Angle on the Marginal Fit of Zirconia All-ceramic Crown
Recommendations
Search

지대주 경사각이 지르코니아 전부도재관의 변연적합도에 미치는 영향

논문 기본 정보

Type
Academic journal
Author
Lee, Seo-Yeon (부산가톨릭대학교 보건과학대학 치기공학과) Chung, In-Sung (부산가톨릭대학교 보건과학대학 치기공학과) Jeon, Byung-Wook (부산가톨릭대학교 보건과학대학 치기공학과)
Journal
The Korean Academy of Dental Technology 대한치과기공학회지 대한치과기공학회지 제38권 제3호
Published
2016.1
Pages
111 - 117 (7page)

Usage

cover
The Effect of Abutment Inclined Angle on the Marginal Fit of Zirconia All-ceramic Crown
Ask AI
Recommendations
Search

Research history (2)

  • Are you curious about the follow-up research of this article?
  • You can check more advanced research results through related academic papers or academic presentations.
  • Check the research history of this article

Abstract· Keywords

Report Errors
Purpose: The present study was performed to investigate the effect of abutment inclined angle on the marginal fit of zirconia all-ceramic crown. Methods: The Ti abutments with 3 different inclined angle($2^{\circ}$, $4^{\circ}$ and $6^{\circ}$) were fabricated. The zirconia copings were fabricated for each abutment by using dental CAD/CAM system. The manufactured zirconia copings were duplicated through silicone replica technique, and a replicated specimen was sectioned in the center of bucco-lingual and mesio-distal axial to measure the marginal fit by using a stereo microscope. The results were analyzed using a one-way ANOVA with SPSS 22.0 for Windows(${\alpha}=0.05$). Results: On the bucco-lingual axial, marginal fit was the RL3($41.5{\pm}3.4{\mu}m$), RL2($44.3{\pm}4.3{\mu}m$) and RL1($47.5{\pm}5.7{\mu}m$), respectively. On the mesio-distal axial, marginal fit was the RL3($41.1{\pm}3.7{\mu}m$), RL2($45.7{\pm}5.3{\mu}m$) and RL1($46.2{\pm}4.5{\mu}m$), respectively. One-way ANOVA showed statistically significant difference between groups for marginal fit(p<0.05). Conclusion: For marginal fit of the abutments inclined angle, RL3 specimen was superior. The abutment inclined angle had influence on marginal fit of the zirconia copings. The marginal fit of each group were within clinically acceptable range.

Contents

No content found

References (26)

Add References

Recommendations

It is an article recommended by DBpia according to the article similarity. Check out the related articles!

Related Authors

Recently viewed articles

Comments(0)

0

Write first comments.