메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
권순용 (건국대학교병원 영상의학과) 임우택 (건국대학교병원 영상의학과) 강충환 (건국대학교병원 영상의학과) 김경수 (건국대학교병원 영상의학과) 김순배 (건국대학교병원 영상의학과) 김현수 (신구대학교 방사선과)
저널정보
대한디지털의료영상학회 대한디지털의료영상학회논문지 대한디지털의료영상학회논문지 제15권 제2호
발행연도
2013.1
수록면
55 - 61 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
The purpose of this study is to evaluate image blurring according to variation of the ETL and propose the clinically appropriate ETL range. SIEMENS MAGNETOM Skyra 3.0T and 20 channel head coil were used for the study. MRI phantom was kept the lines horizontally to three direction(X,Y,Z) of the coil and T1, T2 weighted images that used the fast spin echo technique acquired. The ETL with increase of 10 was applied from 10 to 80. In addition, the ETL with increase of 1 was applied in the interval statistically significant differences occurred. And T1, T2 weighted images that used the conventional spin echo technique acquired to compare image blurring of the images that used the fast spin echo technique. The slope of lattice in the images was measured using Image J 1.47v program to evaluate image blurring. And image blurring was determined by the degree of the slope. The statistical significance of both techniques was evaluated by the Kruskal-Wallis test of the SPSS 17.0v. And the correlation of the ETL and image blurring was evaluated quantitatively by regression analysis. The slope of the T1, T2 weighted images that used fast spin echo technique decreased as contrasted with conventional spin echo technique. In the result of the Kruskal-Wallis test, the T1, T2 weighted images that used fast spin echo technique made a significant difference with conventional spin echo technique. Particularly, in the Tomhane' T2 test, the T1, T2 weighted images made a significant difference from ETL 22 and 31 respectively. In the result of the regression analysis, the R-squared of the T1, T2 weighted images are 0.762 and 0.793. It is difficult to apply the long ETL in the T1 weighted image caused by the short TR and multi-slices study. Therefore, clinical impact according to variation of the ETL is very slight in the T1 weighted images. But the application of the proper ETL is demanded in T2 weighted images using the fast spin echo technique in order to prevent image blurring.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0