메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
김재덕 (조선대학교 치과대학 구강악안면방사선학교실)
저널정보
대한영상치의학회 치과방사선 치과방사선 제29권 제1호
발행연도
1999.1
수록면
33 - 42 (10page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0