메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

The effect of the improperly scanned scan body images on the accuracy of virtual implant positioning in computer-aided design software
추천
검색

The effect of the improperly scanned scan body images on the accuracy of virtual implant positioning in computer-aided design software

논문 기본 정보

자료유형
학술저널
저자정보
저널정보
대한치과보철학회 The Journal of Advanced of Prosthodontics The Journal of Advanced of Prosthodontics 제12권 제3호 KCI Accredited Journals
발행연도
2020.1
수록면
107 - 113 (7page)

이용수

표지
The effect of the improperly scanned scan body images on the accuracy of virtual implant positioning in computer-aided design software
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
PURPOSE. The aim of this study was to examine the importance of the defect-free scanning of a scan body by assessing the accuracy of virtual implant positioning in computer-aided design (CAD) software when the scan body image is improperly scanned. MATERIALS AND METHODS. A scan body was digitized in a dentiform model using an intraoral scanner, and scanned images with differing levels of image deficiency were generated: 5%, 10%, and 15% deficiency in the flat or rounded area. Using a best-fit image matching algorithm on each of the deficient scan body images, corresponding virtual implants were created. The accuracy of the implant position was evaluated by comparing the linear and angular discrepancies between the actual and virtual positions of the implant. Kruskal-Wallis tests and Mann-Whitney U tests with Bonferroni correction were used to determine the statistical differences among the seven scanned image deficiency groups (α = .05). RESULTS. In general, the linear and angular discrepancies of the implant position in the software increased as the deficiency of the scan body images increased. A 15% scan body image deficiency generated larger discrepancies than deficiency of 5% and 10%. The difference of scan defect position, flat or rounded area, did not affect the accuracy of virtual implant orientation at 5% and 10% deficiency level, but did affect the accuracy at 15% deficiency level. CONCLUSION. Deficiencies in the scanned images of a scan body can decrease the accuracy of the implant positioning in CAD software when the defect is large, thus leading to the incorrect fabrication of implant prostheses.

목차

등록된 정보가 없습니다.

참고문헌 (32)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0