메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Seongho Kim (Daejeon Health Institute) Sejong Yoo (Daejeon Health Institute) Mincheol Jeon (Daejeon Health Institute) Jinseo Park (Konkuk University Medical Center) Soonyong Kwon (Konkuk University Medical Center) Hyunkeun Jeong (Bracco Imaging Korea) Jiseong Jang (Asan Medical Center) Jaehyun Song (Konkuk University Medical Center)
저널정보
한국자기학회 Journal of Magnetics Journal of Magnetics Vol.24 No.4
발행연도
2019.12
수록면
719 - 724 (6page)
DOI
10.4283/JMAG.2019.24.4.719

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
This study evaluated the effects of applying the compress-sensing technique and the increase of the CS factor on the quality of the image in the test using the time-of-flight sequence. A 3D TOF MRA test was performed while maintaining a constant flow rate (2.0 ml/sec) by connecting an auto-injector to a self-fabricated flow phantom. Images were obtained by applying the 3D TOF sequence without CS and with CS to evaluate the difference in image quality with or without application of the CS technique. Moreover, in order to analyze the quality of images according to the CS factor, images were obtained while increasing the CS factor from 1.2 to 1.8 by 0.2. The examination time was 44 seconds when the CS technique was not used. When the CS technique was applied, the examination time decreased to 30, 27, 25, and 23 with the CS factor of 1.2, 1.4, 1.6, and 1.8, respectively. On the other hand, the application of the CS technique did not change the SNR or the CNR of the image significantly (p > 0.05). Moreover, the SNR and the CNR of the image were not significantly affected by the changes in the CS factor (p > 0.05). However, as the CS factor increased, the similarity and precision decreased more than in the images where the CS technique was not used. The application of the CS technique to the TOF MRA test can reduce the examination time drastically without changing SNR and CNR. However, we found that, as the CS factor increased, the similarity and precision decreased more than in the test without the CS technique. Therefore, it is necessary to continuously verify the effectiveness of the CS technique and study it more.

목차

1. Introduction
2. Materials and Method
3. Result
4. Discussion
5. Conclusion
References

참고문헌 (30)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0